ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5995-01-385-9345, 5995013859345
CABLE ASSEMBLY,POWER,ELECTRICAL

Federal Supply Classification
FSC 5995 - Cable, Cord, and Wire Assemblies: Communication Equipment
National Item Identification Number
NIIN 013859345
Codification Country
United States
Item Name Code
INC 00485
Criticality
(Y) This item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5995-01-385-9345
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5995-01-385-9345


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5995-01-385-9345

National Stock Number (NSN) 5995-01-385-9345, or NIIN 013859345, (cable assembly,power,electrical) was assigned January 22, 1994 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on May 02, 2005, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00485. [A DEFINITE CONTINUOUS LENGTH OF CABLE,POWER,ELECTRICAL HAVING ONE OR BOTH ENDS PROCESSED AND/OR TERMINATED IN FITTINGS WHICH PROVIDE FOR CONNECTION TO OTHER ITEMS. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE. FOR ITEMS WHICH THE RATED WORKING VOLTAGE IS LESS THAN 300 VOLTS, SEE: CABLE ASSEMBLY,SPECIAL PURPOSE,ELECTRICAL. EXCLUDES: CABLE AND CONDUIT ASSEMBLY,ELECTRICAL AND ITEMS HAVING BRANCHES OR FORKS. SEE ALSO WIRING HARNESS.]. This item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5995013859345 does not contain precious metals.

This NSN is associated to Schedule B 9030400000: other instruments and apparatus, specially designed for telecommunications (for examle, cross-talk meters, gain measuring instruments etc). The Schedule B End Use is listed as telecommunications equipment. NAICS classification category 334515: instrument manufacturing for measuring and testing electricity and electrical signals.

This information was last updated on .


Technical Characteristics

TERMINATION TYPE
(AKRZ) CONNECTOR PLUG BOTH ENDS ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR
(BLNZ) 41 ALL CONDUCTORS
END ITEM IDENTIFICATION
(AGAV) GOLDWING II; 5895-01-300-2299
ACCESSORY WIRE TYPE AND QUANTITY
(AWTB) 1 GROUND
CONDUCTOR QUANTITY
(AMQN) 2
CONDUCTOR FORM
(CXCW) UNABLE TO DECODE
CRITICALITY CODE JUSTIFICATION
(CRTL) FEAT
CROSS SECTION OUTSIDE DIAMETER
(ADVL) 0.246 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLE
(AAGR) ROUND
OVERALL LENGTH
(AAJU) 72.250 INCHES
SPECIAL FEATURES
(FEAT) ASSEMBLY USES PVC JACKET WITHOUT WAIVER, PROHIBITED IN AEROSPACE APPLICATIONS
ROUND CONDUCTOR SIZE
(CXDC) UNABLE TO DECODE
STRAND AWG SIZE PER CONDUCTOR
(CXDG) UNABLE TO DECODE
STRAND QUANTITY PER CONDUCTOR
(BLNZ) UNABLE TO DECODE
STYLE DESIGNATOR
(STYL) INTERNAL AND EXTERNAL CONNECTOR
TERMINATION TYPE
(AKRZ) UNABLE TO DECODE
UNABLE TO DECODE
(MATT) UNABLE TO DECODE
CONDUCTOR FORM
(CXCW) STRANDED ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR
(CXDG) 34 ALL CONDUCTORS
ROUND CONDUCTOR SIZE
(CXDC) 18 AWG ALL CONDUCTORS
MATERIAL
(MATT) PLASTIC POLYVINYL CHLORIDE (PVC) 1ST POSITION JACKET ALL CONDUCTORS
III CONDUCTOR QUANTITY
(AMQN) 2
MATERIAL
(MATT) COPPER CORE CONDUCTOR ALL CONDUCTORS

Manufacturer Part Numbers


Related Inventory

dc4045299
4045299
Condition NE
MOLYKOTE G-RAPI
Readily Available
dc4045238
4045238
Condition NE
DC OR-2000 STD
Readily Available
dc4045667
131798
Condition NE
MOLYKOTE HSC PL
Readily Available
dc4045284
4045284
Condition NE
MOLYKOTE G-RAPI
Readily Available
799VA0
WELC4045
Condition NE
Basic Etching S
Readily Available
45GX21
CAC40-450 X 6
Condition NE
Charge Air Cool
Readily Available
dc4045666
12024755
Condition NE
MOLYKOTE G-RAPI
Readily Available
dc4045662
12024746
Condition NE
MOLYKOTE 1000 P
Readily Available
dc4045343
4045343
Condition NE
MOLYKOTE P74 AN
Readily Available
dc4045291
4045291
Condition NE
MOLYKOTE DOWSIL
Readily Available
dc4045288
4045288
Condition NE
MOLYKOTE HSC PL
Readily Available
dc4045285
4045285
Condition NE
MOLYKOTE U-N Pa
Readily Available
dc4045326
12111955
Condition NE
MOLYKOTE P-40 A
Readily Available
dc4045320
12113270
Condition NE
MOLYKOTE DX EXT
Readily Available
NAS77C4-045
Readily Available


 
Top