NSN 6105-00-418-9648, 6105004189648
MOTOR,DIRECT CURRENT

Federal Supply Classification
FSC 6105 - Motors, Electrical
National Item Identification Number
NIIN 004189648
Codification Country
United States
Item Name Code
INC 16350
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6105-00-418-9648
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6105-00-418-9648


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6105-00-418-9648

National Stock Number (NSN) 6105-00-418-9648, or NIIN 004189648, (motor,direct current) was assigned January 1, 1963 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Feb 02, 2005, this NSN's acquisition method was noted as: Not established. Not established.

This NSN is assigned to Item Name Code (INC) 16350. [A MOTOR WHICH IS DESIGNED FOR OPERATION FROM A DIRECT CURRENT SOURCE. EXCLUDES:MOTOR, ENGINE STARTER, ELECTRICAL. SEE ALSO MOTOR, CONTROL.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6105004189648 contains an unknown precious metal.

This NSN is associated to Schedule B 8501322000: dc motors of an output exceeding 750 w but not exceeding 14.92 kw. The Schedule B End Use is listed as industrial engines. NAICS classification category 335312: motor and generator manufacturing.

This information was last updated on .


Technical Characteristics

LENGTH OF SHAFT FROM HOUSING
(CWCS) 9.375 INCHES FIRST END
CONNECTION TYPE AND VOLTAGE RATING IN VOLTS
(CWGQ) 115.0 LINE TO NEUTRAL SINGLE INPUT
SHAFT DIAMETER
(ABWV) 1.6250 INCHES NOMINAL IDENTICAL ENDS
SHAFT ROTATION DIRECTION
(AKCT) CLOCKWISE IDENTICAL ENDS OR COUNTERCLOCKWISE IDENTICAL ENDS
LENGTH OF SHAFT FROM HOUSING
(CWCS) 2.000 INCHES SECOND END
III OVERALL LENGTH
(AAJU) 32.437 INCHES
KEYWAY WIDTH
(ABRR) 0.3750 INCHES NOMINAL IDENTICAL ENDS
SHAFT CENTER TO MOUNTING SURFACE DISTANCE
(CWDM) 7.000 INCHES IDENTICAL ENDS
SHAFT ROTATION DIRECTION
(AKCT) CLOCKWISE OR COUNTERCLOCKWISE IDENTICAL ENDS
CURRENT RATING IN AMPS
(CWGL) 18.500 SINGLE INPUT
INCLOSURE FEATURE
(ANPZ) OPEN PROTECTED
ENCLOSURE FEATURE
(ANPZ) OPEN PROTECTED
CONNECTION TYPE AND VOLTAGE RATING IN VOLTS
(CWGQ) UNABLE TO DECODE
COOLING METHOD
(BFMF) SELF-VENTILATED
CURRENT RATING IN AMPS
(CWGL) UNABLE TO DECODE
CURRENT RATING METHOD
(BKPB) LOAD
DUTY CYCLE
(AKPS) INTERMITTENT
FEATURES PROVIDED
(CBBL) HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION
INCLOSURE SPECIFICATION
(BKPQ) COMMERCIAL
KEYWAY DEPTH
(ABRV) UNABLE TO DECODE
KEYWAY WIDTH
(ABRR) UNABLE TO DECODE
LENGTH OF SHAFT FROM HOUSING
(CWCS) UNABLE TO DECODE
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 4 UNTHREADED HOLE
MOUNTING METHOD
(AXGY) FIXED BASE
NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(CWDT) 11.500 INCHES
NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(CWFY) 11.000 INCHES
OVERALL HEIGHT
(AAJT) 17.875 INCHES
OVERALL LENGTH
(AAJU) 32.437 INCHES
OVERALL WIDTH
(AAJV) 14.438 INCHES
POWER RATING
(CNXS) UNABLE TO DECODE
ROTOR SPEED RATING IN RPM
(CWFX) 350.0 SINGLE FULL LOAD
SHAFT CENTER TO MOUNTING SURFACE DISTANCE
(CWDM) UNABLE TO DECODE
SHAFT DIAMETER
(ABWV) UNABLE TO DECODE
SHAFT END CHARACTERISTIC
(CWHZ) UNABLE TO DECODE
TEMP RATING
(CWDY) 50.0 OPERATING CELSIUS
TIME INTERVAL
(BFLT) 1.0 HOURS MAXIMUM ON
WINDING TYPE
(AXCP) SHUNT WOUND W/COMMUTATING POLES
KEYWAY DEPTH
(ABRV) 0.1875 INCHES NOMINAL IDENTICAL ENDS
POWER RATING
(CNXS) 2.0000 HORSEPOWER OUTPUT
TEMP RATING
(CWDY) 50.0 OPERATING DEG CELSIUS
SHAFT END CHARACTERISTIC
(CWHZ) A9 SINGLE STYLE IDENTICAL ENDS

Manufacturer Part Numbers


Related Inventory



 
Top