ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6110-01-528-5661, 6110015285661
CONTACTOR,MAGNETIC

Federal Supply Classification
FSC 6110 - Electrical Control Equipment
National Item Identification Number
NIIN 015285661
Codification Country
United States
Item Name Code
INC 31517
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: We have 2 qualified suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6110-01-528-5661
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6110-01-528-5661


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6110-01-528-5661

National Stock Number (NSN) 6110-01-528-5661, or NIIN 015285661, (contactor,magnetic) was assigned March 17, 2005 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts. ISO Group has several sources of supply for this NSN.

This part number has not been procured by the US Government in over 5 years.

This NSN is unique to one weapons system.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Sep 02, 2006, this NSN's acquisition method was noted as: Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. Acquisition of this part is restricted to source(s) specified on "Source Control", "Altered Item" or "Selected Item" drawings/documents. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 31517. [AN ITEM CONSISTING OF CONTACTS, A MAGNETIC CORE, AND A COIL WITH OR WITHOUT INCLOSURE WHICH IS USED TO REPEATEDLY ESTABLISH AND BREAK A CIRCUIT. THE ITEM DOES NOT PROVIDE OVERLOAD PROTECTION AND IS NOT USED IN LINE TO CONTROL ANY OTHER ELECTRICAL CONTROLS. EXCLUDES RELAY, ELECTROMAGNETIC AND STARTER, MOTOR.L CIRCUIT. EXLUDES RELAY, ELECTRO-MAGNETIC AND STARTER, MOTOR.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6110015285661 does not contain precious metals.

This NSN is associated to Schedule B 8543909000: electrical machines and apparatus parts, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335999: all other miscellaneous electrical equipment and component manufacturing.

This information was last updated on .


Technical Characteristics

ACCESSORY CONTROLLING AGENCY
(AKVY) NAVICP-M/DRS
ACCESSORY IDENTIFYING NUMBER
(AKVZ) 6967ED572 DRAWING NO.
FUSE CURRENT RATING IN AMPS
(ANDG) 3.0 AND 5.0 AND 10.0
PHASE
(FAAZ) THREE
ENCLOSURE FEATURE
(ANPZ) ENVIRONMENTAL PROOF AND DRIPPROOF
END ITEM IDENTIFICATION
(AGAV) FUEL OIL SERVICE PUMP CONTROLLER
AC VOLTAGE RATING
(ACYN) 440.0 VOLTS NOMINAL
ACTUATION METHOD
(AFLW) MAGNETIC
AMBIENT TEMP
(ANDX) 50.0 CELSIUS
AMP SIZE RATING
(ANRH) 250.0
CONTROL TYPE
(AQZF) REMOTE
DUTY CYCLE
(AKPS) CONTINUOUS
FEATURES PROVIDED
(CBBL) ACCESSORY LOCATION INTERNAL AND CIRCUIT PROTECTION FUSE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION
(ABFE) DRIPTIGHT
HORSEPOWER RATING
(ANCY) 10.000 AND 5.000
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) CONTROLLER,AC MAGNETIC SIZE 1/0
PERFORMANCE TYPE
(AGLD) MANUAL
MOUNTING CONFIGURATION
(ALGC) 6-0.531 DIAMETER HOLES FOR 0.500 MOUNTING BOLTS
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN
(ANQC) DESIGNED PER NEMA STD
OPERATING VOLTAGE CHARACTERISTIC
(ANCN) REDUCED
OVERALL HEIGHT
(ABKW) 26.120 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 26.800 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 18.120 INCHES NOMINAL
SPECIAL FEATURES
(FEAT) RUBBER GASKETED DOOR,TOP & SIDES
SWITCH FUNCTIONAL POSITIONS
(ANRK) EMERGENCY AND EMERGENCY START AND EMERGENCY STOP AND FAST AND FAST START AND FAST RESET EMERGENCY RUN AND HIGH EMERGENCY RUN AND HIGH-LOW AND HIGH SPEED AND LOW-HIGH AND MANUAL AND REMOTE AND RESET AND START AND SLOW AND STOP AND SLOW RESET EMERGENCY RUN AND REMOTE CONTROL OFF AND REMOTE CONTROL ON
LOAD PROTECTION TYPE
(ANDW) OVERLOAD
SPEED ADJUSTMENTS
(ABBB) TWO SPEED
FREQUENCY IN HERTZ
(FREQ) 60.0
FREQUENCY RATING
(ACZB) 60.0 HERTZ NOMINAL
ACTUATOR VOLTAGE
(ANDE) 440.0 AC
FUSE ACCOMMODATION QUANTITY
(AGUE) 4
FULL VOLTAGE RESTORING METHOD
(ANCQ) MANUAL ACCELERATION
AMBIENT TEMP
(ANDX) 50.0 DEG CELSIUS
SIZE DESIGNATOR
(AJXE) 1
VOLTAGE REDUCTION METHOD
(ANCP) AUTOTRANSFORMER
INCLOSURE FEATURE
(ANPZ) ENVIRONMENTAL PROOF AND DRIPPROOF

Manufacturer Part Numbers


Related Inventory

3CGL7
PVC 638-TB6F-F
Condition NE
Manual Two-Way
Readily Available
3CGL8
PVC 638-TB6M-F
Condition NE
Manual Two-Way
Readily Available
38TB6
Terminal Boards
Readily Available
38TB6F
Terminal Boards
Readily Available
MILT55164/2-38TB6
Readily Available
MILT551L4/238TB6
Readily Available


 
Top