NSN 6120-01-531-6342, 6120015316342
TRANSFORMER,POWER

Federal Supply Classification
FSC 6120 - Transformers: Distribution and Power Station
National Item Identification Number
NIIN 015316342
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6120-01-531-6342
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6120-01-531-6342


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6120-01-531-6342

National Stock Number (NSN) 6120-01-531-6342, or NIIN 015316342, (transformer,power) was assigned July 18, 2005 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, there are no suppliers listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years, with the most recent procurement date of Mar 21, 2012. There have been 12 contracts issued for this part number, with 12 awards given. There is minimal competition for this NSN. The US Government has awarded contracts to 3 different suppliers. The last contract numbers awarded were: SPM7MC12M3494, SPM7MC12V2760, SPM7MC12V2040, SPM7MC11VA003, SPM7MC11V8277. The total value of the awarded contracts has been US$ 47,927.98.

This NSN is somewhat common among different platforms, belonging to 4 different weapons systems.

There has been a small amount of demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jul 25, 2009, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The data needed to produce this item from additional sources is not physically available. Valid AMCs: 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6120015316342 does not contain precious metals.

This information was last updated on .


Technical Characteristics

FREQUENCY RATING
(ACZB) 50.0 HERTZ MINIMUM ALL COMPONENTS AND 60.0 HERTZ MAXIMUM ALL COMPONENTS
WINDING OPERATING VOLTAGE
(CWJS) 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 100.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY
END ITEM IDENTIFICATION
(AGAV) 6115-01-296-1463
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 5.500 INCHES NOMINAL ALL MOUNTING FACILITIES SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 3.690 INCHES NOMINAL ALL MOUNTING FACILITIES SINGLE CENTER GROUP
FREQUENCY RATING
(ACZB) 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM ALL COMPONENTS
INCLOSURE TYPE
(AKNA) PARTIALLY INCLOSED, DOUBLE SHELL
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) HIGH POWER INTERNATIONAL TRANSFORMER
MOUNTING FACILITY QUANTITY
(AKPV) 4 SINGLE GROUP
MOUNTING METHOD
(AXGY) SLOT SINGLE GROUP
MOUNTING SLOT WIDTH
(ABTD) 0.313 INCHES NOMINAL AND 0.688 INCHES NOMINAL SINGLE GROUP
OVERALL HEIGHT
(ABKW) 6.060 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 7.060 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 5.040 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY
(TTQY) 20 SCREW
WINDING OPERATING VOLTAGE
(CWJS) 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 215.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 230.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 230.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 215.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD PRIMARY