ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6130-01-363-6655, 6130013636655
POWER SUPPLY

Federal Supply Classification
FSC 6130 - Converters, Electrical, Nonrotating
National Item Identification Number
NIIN 013636655
Codification Country
United States
Item Name Code
INC 00740
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6130-01-363-6655
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6130-01-363-6655


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6130-01-363-6655

National Stock Number (NSN) 6130-01-363-6655, or NIIN 013636655, (power supply) was assigned September 3, 1992 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 3 suppliers. Today, 3 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00740. [A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR,VIBRATOR; VIBRATOR,INTERRUPTER; VIBRATOR,SELF-RECTIFYING; INVERTOR,POWER,STATIC WITH A TRANSFORMER AND RECTIFIES EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACTS OF A VIBRATOR,SELF-RECTIFYING OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER,DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. THE ITEM MAY HAVE SPECIAL INPUT, OUTPUT, CONTROL OR OTHER FACILITIES FOR APPLICATIONS IN SPECIALIZED ENVIRONMENTS SUCH AS MEDICAL, DENTAL OR OTHER OPERATIONS. EXCLUDES BATTERY CHARGERS AND ROTATING MACHINERY TYPES OF ITEMS, SUCH AS MOTOR GENERATORS AND ENERATORS AND DYNAMOTORS.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6130013636655 does not contain precious metals.

This NSN is associated to Schedule B 8504900080: static converter & inductor parts, nesoi. The Schedule B End Use is listed as generators, accessories. NAICS classification category 334419: other electronic component manufacturing.

This information was last updated on .


Technical Characteristics

OUTPUT CONNECTION QUANTITY
(CWHF) 1 2ND POWER OUTPUT
OUTPUT CONNECTION QUANTITY
(CWHF) UNABLE TO DECODE
OUTPUT CONTROL LOCATION
(CWHC) FRONT PANEL 4TH POWER OUTPUT
INPUT CONNECTION QUANTITY
(CWHT) UNABLE TO DECODE
ELECTRICAL POWER SOURCE RELATIONSHIP
(AKWC) OPERATING
END ITEM IDENTIFICATION
(AGAV) PROCESSOR UNIT
ENVIRONMENTAL PROTECTION
(ADZC) GENERAL PURPOSE
FEATURES PROVIDED
(CBBL) OVER VOLTAGE PROTECTOR AND EMI FILTER
INPUT CONNECTION QUANTITY
(CWHT) 1 FIRST ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION QUANTITY
(CWHT) 1 SECOND ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION TYPE
(CWHQ) TERMINAL STRIP FIRST ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION TYPE
(CWHQ) TERMINAL STRIP SECOND ALTERNATE OPERATING POWER RQMT
INPUT CURRENT RATING
(CWHM) 200.0 AC AMPERES NOMINAL FIRST ALTERNATE OPERATING POWER RQMT
INPUT CURRENT RATING
(CWHM) 300.0 AC AMPERES NOMINAL SECOND ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 115.0 AC VOLTS NOMINAL FIRST ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 230.0 AC VOLTS NOMINAL SECOND ALTERNATE OPERATING POWER RQMT
INPUT PHASE
(ANPM) SINGLE SECOND ALTERNATE OPERATING POWER RQMT
INPUT PHASE
(ANPM) SINGLE FIRST ALTERNATE OPERATING POWER RQMT
OVERALL LENGTH
(ABHP) 14.880 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 9.000 INCHES NOMINAL
OPERATING AMBIENT TEMP RANGE
(AYNH) +0.1 TO 70.0 CELSIUS
OUTPUT CONNECTION QUANTITY
(CWHF) 1 FIRST POWER OUTPUT
OUTPUT CONNECTION QUANTITY
(CWHF) 1 FOURTH POWER OUTPUT
OUTPUT CONNECTION QUANTITY
(CWHF) 1 SECOND POWER OUTPUT
OUTPUT CONNECTION QUANTITY
(CWHF) 1 THIRD POWER OUTPUT
OUTPUT CONNECTION TYPE
(CWHJ) TERMINAL STRIP FIRST POWER OUTPUT
OUTPUT CONNECTION TYPE
(CWHJ) TERMINAL STRIP THIRD POWER OUTPUT
OUTPUT CONNECTION TYPE
(CWHJ) TERMINAL STRIP FOURTH POWER OUTPUT
OUTPUT CONNECTION TYPE
(CWHJ) TERMINAL STRIP SECOND POWER OUTPUT
OUTPUT CONTROL LOCATION
(CWHC) FRONT PANEL FIRST POWER OUTPUT
OUTPUT CONTROL LOCATION
(CWHC) FRONT PANEL FOURTH POWER OUTPUT
OUTPUT CONTROL LOCATION
(CWHC) FRONT PANEL SECOND POWER OUTPUT
OUTPUT CONTROL LOCATION
(CWHC) FRONT PANEL THIRD POWER OUTPUT
OUTPUT CURRENT RATING
(CWGH) 10.0 DC AMPERES NOMINAL FIRST POWER OUTPUT
OUTPUT CURRENT RATING
(CWGH) 10.0 DC AMPERES NOMINAL SECOND POWER OUTPUT
OUTPUT CURRENT RATING
(CWGH) 19.0 DC AMPERES NOMINAL THIRD POWER OUTPUT
OUTPUT CURRENT RATING
(CWGH) 200.0 DC AMPERES NOMINAL FOURTH POWER OUTPUT
OUTPUT VOLTAGE RATING
(APPA) 12.0 DC VOLTS NOMINAL FIRST POWER OUTPUT
OUTPUT VOLTAGE RATING
(APPA) 12.0 DC VOLTS NOMINAL SECOND POWER OUTPUT
OUTPUT VOLTAGE RATING
(APPA) 5.0 DC VOLTS NOMINAL THIRD POWER OUTPUT
OUTPUT VOLTAGE RATING
(APPA) 5.0 DC VOLTS NOMINAL FOURTH POWER OUTPUT
OVERALL HEIGHT
(ABKW) 5.000 INCHES NOMINAL
SPECIAL FEATURES
(FEAT) REFERANCE PROCESSOR UNIT T.O.31R2-2GSQ235,FIG 8-4 INDX 183
VENTILATION DESIGN TYPE
(CWKG) CONVECTION
INPUT FREQUENCY RATING
(APTQ) 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING
(APTQ) 47.0 HERTZ MINIMUM AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
INPUT PHASE
(ANPM) SINGLE 2ND ALTERNATE OPERATING POWER RQMT
OUTPUT VOLTAGE RATING
(APPA) UNABLE TO DECODE
INPUT FREQUENCY RATING
(APTQ) 47.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
INPUT PHASE
(ANPM) UNABLE TO DECODE
OUTPUT CONTROL LOCATION
(CWHC) FRONT PANEL 1ST POWER OUTPUT
OUTPUT CONTROL LOCATION
(CWHC) FRONT PANEL 3RD POWER OUTPUT
INPUT CONNECTION TYPE
(CWHQ) UNABLE TO DECODE
INPUT FREQUENCY RATING
(APTQ) 47.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
OUTPUT CONNECTION TYPE
(CWHJ) TERMINAL STRIP 4TH POWER OUTPUT
OPERATING AMBIENT TEMP RANGE
(AYNH) +0.1/+70.0 DEG CELSIUS
INPUT VOLTAGE RATING
(APNX) 115.0 AC POUNDS PER HOUR WET 1ST ALTERNATE OPERATING POWER RQMT
OUTPUT CONTROL LOCATION
(CWHC) UNABLE TO DECODE
OUTPUT CONNECTION TYPE
(CWHJ) TERMINAL STRIP 3RD POWER OUTPUT
INPUT CONNECTION TYPE
(CWHQ) TERMINAL STRIP 1ST ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) UNABLE TO DECODE
INPUT CONNECTION TYPE
(CWHQ) TERMINAL STRIP 2ND ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION QUANTITY
(CWHT) 1 1ST ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION QUANTITY
(CWHT) 1 2ND ALTERNATE OPERATING POWER RQMT
OUTPUT CONTROL LOCATION
(CWHC) FRONT PANEL 2ND POWER OUTPUT
OUTPUT CONNECTION QUANTITY
(CWHF) 1 3RD POWER OUTPUT
OUTPUT CONNECTION TYPE
(CWHJ) UNABLE TO DECODE
INPUT PHASE
(ANPM) SINGLE 1ST ALTERNATE OPERATING POWER RQMT
OUTPUT CURRENT RATING
(CWGH) UNABLE TO DECODE
OUTPUT CONNECTION TYPE
(CWHJ) TERMINAL STRIP 1ST POWER OUTPUT
INPUT VOLTAGE RATING
(APNX) 230.0 AC POUNDS PER HOUR WET 2ND ALTERNATE OPERATING POWER RQMT
OPERATING AMBIENT TEMP RANGE
(AYNH) +0.1 TO 70.0 DEG CELSIUS
OUTPUT CONNECTION QUANTITY
(CWHF) 1 1ST POWER OUTPUT
OUTPUT CONNECTION QUANTITY
(CWHF) 1 4TH POWER OUTPUT
OUTPUT CONNECTION TYPE
(CWHJ) TERMINAL STRIP 2ND POWER OUTPUT
INPUT CURRENT RATING
(CWHM) UNABLE TO DECODE


Related Inventory



 
Top