ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6130-01-398-9105, 6130013989105
POWER SUPPLY

Federal Supply Classification
FSC 6130 - Converters, Electrical, Nonrotating
National Item Identification Number
NIIN 013989105
Codification Country
United States
Item Name Code
INC 00740
Criticality
(Y) This item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6130-01-398-9105
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6130-01-398-9105


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6130-01-398-9105

National Stock Number (NSN) 6130-01-398-9105, or NIIN 013989105, (power supply) was assigned November 10, 1994 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Sep 02, 2000, this NSN's acquisition method was noted as: Not established. Not established.

This NSN is assigned to Item Name Code (INC) 00740. [A COMPONENT WHICH CONVERTS AVAILABLE ALTERNATING CURRENT OR DIRECT CURRENT ELECTRICAL POWER INTO A FORM REQUIRED TO OPERATE ANOTHER COMPONENT OR SET. THE ITEM MAY CONSIST OF A COMBINATION OF AN INVERTOR,VIBRATOR; VIBRATOR,INTERRUPTER; VIBRATOR,SELF-RECTIFYING; INVERTOR,POWER,STATIC WITH A TRANSFORMER AND RECTIFIES EMPLOYING ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE COMPONENTS, OR THE SYNCHRONIZED SECONDARY CONTACTS OF A VIBRATOR,SELF-RECTIFYING OR MAY CONSIST OF ELECTRON TUBES, SEMICONDUCTOR DIODE OR METALLIC (DRY DISC) TYPE RECTIFIERS AND CAPACITORS IN TRANSFORMERLESS (ALTERNATING CURRENT-DIRECT CURRENT TYPE) CIRCUITS WHICH MAY BE OF THE VOLTAGE-MULTIPLIER TYPE. THE ITEM MAY INCORPORATE A FILTER,DIRECT CURRENT POWER AND PROVISIONS FOR REGULATION OF INPUT AND/OR OUTPUT VOLTAGE. THE ITEM MAY HAVE SPECIAL INPUT, OUTPUT, CONTROL OR OTHER FACILITIES FOR APPLICATIONS IN SPECIALIZED ENVIRONMENTS SUCH AS MEDICAL, DENTAL OR OTHER OPERATIONS. EXCLUDES BATTERY CHARGERS AND ROTATING MACHINERY TYPES OF ITEMS, SUCH AS MOTOR GENERATORS AND ENERATORS AND DYNAMOTORS.]. This item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6130013989105 does not contain precious metals.

This NSN is associated to Schedule B 8504900080: static converter & inductor parts, nesoi. The Schedule B End Use is listed as generators, accessories. NAICS classification category 334419: other electronic component manufacturing.

This information was last updated on .


Technical Characteristics

ELECTRICAL POWER SOURCE RELATIONSHIP
(AKWC) OPERATING
END ITEM IDENTIFICATION
(AGAV) F-15
CRITICALITY CODE JUSTIFICATION
(CRTL) FEAT
INPUT CURRENT RATING
(CWHM) 70.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT
INPUT CURRENT RATING
(CWHM) 70.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT
INPUT CURRENT RATING
(CWHM) 70.0 AC AMPERES NOMINAL 3RD ALTERNATE OPERATING POWER RQMT
INPUT CURRENT RATING
(CWHM) 70.0 AC AMPERES NOMINAL 4TH ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION QUANTITY
(CWHT) 1 2ND ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION QUANTITY
(CWHT) 1 3RD ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION QUANTITY
(CWHT) 1 4TH ALTERNATE OPERATING POWER RQMT
INPUT CONNECTION QUANTITY
(CWHT) 1 1ST ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 120.0 AC VOLTS MINIMUM AND 130.0 AC VOLTS MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING
(APTQ) 48.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING
(APTQ) 48.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING
(APTQ) 48.0 HERTZ MINIMUM 4TH ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 4TH ALTERNATE OPERATING POWER RQMT
INPUT FREQUENCY RATING
(APTQ) 48.0 HERTZ MINIMUM 3RD ALTERNATE OPERATING POWER RQMT AND 62.0 HERTZ MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT
INPUT PHASE
(ANPM) SINGLE 1ST ALTERNATE OPERATING POWER RQMT
INPUT PHASE
(ANPM) SINGLE 2ND ALTERNATE OPERATING POWER RQMT
INPUT PHASE
(ANPM) SINGLE 3RD ALTERNATE OPERATING POWER RQMT
INPUT PHASE
(ANPM) SINGLE 4TH ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 220.0 AC VOLTS MINIMUM AND 230.0 AC VOLTS MAXIMUM 3RD ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 230.0 AC VOLTS MINIMUM AND 250.0 AC VOLTS MAXIMUM 4TH ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 90.0 AC VOLTS MINIMUM AND 110.0 AC VOLTS MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT
OPERATING AMBIENT TEMP RANGE
(AYNH) +0.1 TO 50.0 DEG CELSIUS
OUTPUT CONNECTION QUANTITY
(CWHF) 1 SINGLE POWER OUTPUT
OUTPUT CONNECTION TYPE
(CWHJ) CONNECTOR, RECEPTACLE SINGLE POWER OUTPUT
OUTPUT CONTROL LOCATION
(CWHC) REAR PANEL SINGLE POWER OUTPUT
OUTPUT CURRENT RATING
(CWGH) 0.0 DC MILLIAMPERES MINIMUM SINGLE POWER OUTPUT AND 1.5 DC MILLIAMPERES MAXIMUM SINGLE POWER OUTPUT
OUTPUT VOLTAGE RATING
(APPA) 0.0 DC KILOVOLTS MINIMUM SINGLE POWER OUTPUT AND 30.0 DC KILOVOLTS MAXIMUM SINGLE POWER OUTPUT
OVERALL HEIGHT
(ABKW) 5.250 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 19.000 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 13.110 INCHES NOMINAL
SPECIAL FEATURES
(FEAT) OUTPUT VOLTAGE ANALOG METER, CONTROL SELECTOR SWITCH, VOLTAGE AND CURRENT ADJUSTABLE, LOCAL CONTROL POTENTIOMETER, ELECTROSTATIC SENSITIVE DEVICE
VENTILATION DESIGN TYPE
(CWKG) CONVECTION
INPUT VOLTAGE RATING
(APNX) 120.0 AC POUNDS PER HOUR DRY 2ND ALTERNATE OPERATING POWER RQMT AND 130.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 2ND ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 230.0 AC POUNDS PER HOUR DRY 4TH ALTERNATE OPERATING POWER RQMT AND 250.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 4TH ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 220.0 AC POUNDS PER HOUR DRY 3RD ALTERNATE OPERATING POWER RQMT AND 230.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 3RD ALTERNATE OPERATING POWER RQMT
INPUT VOLTAGE RATING
(APNX) 90.0 AC POUNDS PER HOUR DRY 1ST ALTERNATE OPERATING POWER RQMT AND 110.0 AC POUNDS PER HOUR WITH RETAINING CHAIN 1ST ALTERNATE OPERATING POWER RQMT
OPERATING AMBIENT TEMP RANGE
(AYNH) +0.1/+50.0 DEG CELSIUS

Manufacturer Part Numbers


Related Inventory



 
Top