NSN 6145-00-810-9302, 6145008109302
Cancelled -> Replaced by 6145005787428

Federal Supply Classification
FSC 6145 - Wire and Cable, Electrical
National Item Identification Number
NIIN 008109302
Codification Country
United States
Item Name Code
INC 00798
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6145-00-810-9302
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6145-00-810-9302


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6145-00-810-9302

National Stock Number (NSN) 6145-00-810-9302, or NIIN 008109302, (wire,electrical) was assigned January 1, 1963 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 6145005787428.

There are no manufacturer part numbers associated to this NSN.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00798. [A SINGLE METALLIC CONDUCTOR OF SOLID, STRANDED, OR TINSEL CONSTRUCTION, DESIGNED TO CARRY CURRENT IN AN ELECTRICAL CIRCUIT. IT MAY BE A BARE OR INSULATED, MAY HAVE METALIC COVERING SHEATH, SHIELD OR AND ADDITIONAL JACKET. REFERS TO BULK QUANTITIES ONLY. FOR ITEMS THAT ARE SOLID OR STRANDED, INSULATED OR UNINSULATED, AND HAVE THE CHEMICAL COMPOSITION SPECIFIED BUT NO CONDUCTIVITY (ELECTRICAL PROPERTIES) SEE WIRE,(AS MODIFIED), INCLUDES LITZ WIRE AND INSULATED/UNINSULATED ARMORED, AND GROUND WIRE. EXCLUDES:BRAID, WIRE; FUSE WIRE; RESISTANCE WIRE AND MAGNET WIRE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6145008109302 contains an unknown precious metal.

This NSN is associated to Schedule B 8548900100: electrical parts of machinery or apparatus not specified or included elsewhere in chapter 85. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335999: all other miscellaneous electrical equipment and component manufacturing.

This information was last updated on .


Technical Characteristics

STRAND QUANTITY PER CONDUCTOR
(BLNZ) UNABLE TO DECODE
STRAND AWG SIZE PER CONDUCTOR
(CXDG) UNABLE TO DECODE
COLOR
(HUES) FIRST POSITION COVER SINGLE CONDUCTOR WHITE
CONDUCTOR FORM
(CXCW) SINGLE CONDUCTOR STRANDED
CROSS SECTION OUTSIDE DIAMETER
(ADVL) INCHES NOMINAL 0.535
MATERIAL DOCUMENT AND CLASSIFICATION
(MDCL) CORE CONDUCTOR SINGLE CONDUCTOR ASSN STD ALL MATERIAL RESPONSES AST- B33
MATERIAL DOCUMENT AND CLASSIFICATION
(MDCL) FOURTH POSITION JACKET SINGLE CONDUCTOR MIL SPEC SINGLE MATERIAL RESPONSE -IL---2069-3,TYE 3,GRADE E
MATERIAL DOCUMENT AND CLASSIFICATION
(MDCL) SECOND POSITION BRAID NON-METALLIC SINGLE CONDUCTOR MIL SPEC SINGLE MATERIAL RESPONSE -IL-Y-1-140
MATERIAL
(MATT) CORE CONDUCTOR SINGLE CONDUCTOR COPPER ALLOY 101 OR COPPER ALLOY 102
MATERIAL
(MATT) FIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR PLASTIC POLYVINYL CHLORIDE (PVC)
MATERIAL
(MATT) FOURTH POSITION JACKET SINGLE CONDUCTOR PLASTIC POLYAMIDE NYLON
MATERIAL
(MATT) SECOND POSITION BRAID NON-METALLIC SINGLE CONDUCTOR GLASS FIBER AND FIBER SYNTHETIC
MATERIAL
(MATT) THIRD POSITION SECONDARY INSULATION SINGLE CONDUCTOR PLASTIC POLYVINYL CHLORIDE (PVC)
ROUND CONDUCTOR SIZE
(CXDC) SINGLE CONDUCTOR AWG 0
STRAND AWG SIZE PER CONDUCTOR
(CXDG) 30
STRAND QUANTITY PER CONDUCTOR
(BLNZ) 1045
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION
(STDC) CORE CONDUCTOR SINGLE CONDUCTOR ASSN STD SINGLE TREATMENT RESPONSE AST- B33-63
SURFACE TREATMENT
(SFTT) CORE CONDUCTOR SINGLE CONDUCTOR TIN
TEMP RATING
(ABJH) CELSIUS 105.0
VOLTAGE RATING
(CXFK) SINGLE CONDUCTOR MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0
CONDUCTOR FORM
(CXCW) UNABLE TO DECODE
MATERIAL
(MATT) GLASS FIBER 2ND POSITION BRAID, NON-METALLIC SINGLE CONDUCTOR AND FIBER SYNTHETIC 2ND POSITION BRAID, NON-METALLIC SINGLE CONDUCTOR
SURFACE TREATMENT
(SFTT) TIN SECOND MORTISE
COLOR
(HUES) WHITE SECOND ROW SECOND POSITION HORIZONTAL 4WAY SPLIT DISPLAY DIVISION D
MATERIAL
(MATT) PLASTIC POLYAMIDE 4TH POSITION JACKET SINGLE CONDUCTOR
MATERIAL
(MATT) PLASTIC POLYAMIDE (NYLON) SECOND COMPONENT
VOLTAGE RATING
(CXFK) UNABLE TO DECODE
COLOR
(HUES) WHITE 1ST POSITION COVER SINGLE CONDUCTOR
MATERIAL
(MATT) COPPER ALLOY 101 CORE CONDUCTOR SINGLE CONDUCTOR OR COPPER ALLOY 102 CORE CONDUCTOR SINGLE CONDUCTOR
TEMP RATING
(ABJH) 105.0 DEG CELSIUS
ROUND CONDUCTOR SIZE
(CXDC) UNABLE TO DECODE

Manufacturer Part Numbers