ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6515-00-104-8520, 6515001048520
LIGHT,ENDOSCOPIC INSTRUMENT,FIBE

Federal Supply Classification
FSC 6515 - Medical and Surgical Instruments, Equipment, and Supplies
National Item Identification Number
NIIN 001048520
Codification Country
United States
Item Name Code
INC 46370
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6515-00-104-8520
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6515-00-104-8520


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6515-00-104-8520

National Stock Number (NSN) 6515-00-104-8520, or NIIN 001048520, (light,endoscopic instrument,fibe) was assigned May 27, 1972 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 46370. [A PROTABLE DEVICE WITH FITTED INDIVIDUALLY CONTROLLED LAMPS, MULTIPORT FACE PLATES, INTENSITY CONTROL KNOBS WHICH HAS ONE FOR EACH LAMP WITH ON-OFF SWITCH, AND OTHER RELATED FEATURES. IT INCREASES ILLUMINATION FOR USE ON HEADLIGHTS, ENDOSCOPIC EQUIPMENT AND OTHER ILLUMINATED INSTRUMENTS. MAY ALSO SERVE AS AN AUTOMATIC CIRCUIT BREAKER AND MANY OTHER MEDICAL APPLICATIONS.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6515001048520 does not contain precious metals.

This NSN is associated to Schedule B 9018908000: other instruments and appliances used in medical, surgical, dental or veterinary sciences, nesoi. The Schedule B End Use is listed as medicinal equipment. NAICS classification category 339112: surgical and medical instrument manufacturing.

This information was last updated on .


Technical Characteristics

FREQUENCY IN HERTZ
(FREQ) 50.0 OR 60.0
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) LIGHT ENDOSCOPIC INSTRUMENT FIBER OPTIC W/CASE 120V 50/60HZ
OVERALL HEIGHT
(ABKW) 10.000 INCHES NOMINAL
SPECIAL FEATURES
(FEAT) 60 HZ,AC; IN CARRYING CASE; WITH BLOWER,TRANSFORMER,DIAL CONTROL AND 250 WATT PORTABLE HALOGEN ILLUMINATOR; SHALL BE A FIBER OPTIC LIGHT SOURCE AND CABLE, SUITABLE FOR USE WITH THE HOLINGER, JACKSON AND JESBERG FIBER OPTIC BRONCHOSCOPES, LARYNGOSCOPES AND ESOPHAGOSCOPES,AND ADAPTABLE FOR USE WITH NSNS: 6515-00-403-9868, 6515-00-404-4046, AND 6515-00-404-1347; LIGHT SOURCE SHALL BE CAPABLE OF CONTINUOUS OPERATION ON A NOMINAL 115 VOLT, 60HZ; A CIRCULATIN AIR SYSTEM WITH BLOWER TO DISSIPATE HEAT; A VARIABLE TRANSFORMER WITH DIAL CONTROL TO PERMIT VOLTAGE AND LIGHT INTENSITY FROM ZERO TO FULL OUTPUT.R; A 250 WATT PORTABLE TUNGSTEN HALOGEN LAMP; SHALL HAVE LITTLE OR NO EXTRANEOUS LIGHT LEAKAGE AND BE SUPPLIED WITH A REMOVABLE NOSE CONE TO ACCOMMADATE THE CABLES; SHALL BE SUPPLIED WITH A UL APPROVED 3-PRONG GROUNDED PLUG AND POWER CABLE; SHALL BE SUPPLIED WITH OPERATING INSTRUCTIONS AND SERVICE DATA; UNIT OF ISSUE: EACH
VOLTAGE IN VOLTS
(ELEC) 120.0

Manufacturer Part Numbers


Related Inventory

NRE529318X

Condition NE
Case Constructi
Readily Available
G005293183
CMHT73756
Condition NE
Straight Cut Av
Readily Available
799DE3
22521_12_12
Condition NE
4130 Alloy Stee
Readily Available
820L84
MP5211212
Condition NE
Adjustable Cros
Readily Available
S852112-1EA
Condition NE
11 12-DICHLORO-
Readily Available
2521121
Condition NE
GUIDE
Readily Available
70202-52112-152
Condition FN
SUPPORT
Readily Available
70202-52112-147
Condition FN
CHANNEL*
Readily Available
70202-52112-160
Condition FN
Channel*
Readily Available
70202-52112-137
Condition FN
ANGLE
Readily Available
70202-52112-135
Condition FN
STRINGER*
Readily Available
70202-52112-113
Condition FN
Spacer*
Readily Available
5310-01-529-3186
AS5178K16
Condition NS
NUT
Readily Available
70209-52112-137
Condition FN
STRAP
Readily Available
7671C214-070-521-121
Condition NE
BLANKET
Readily Available
70202-52112-159
Condition FN
Channel
Readily Available


 
Top