ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6515-00-243-9695, 6515002439695
Cancelled -> Replaced by 6515012779372

Federal Supply Classification
FSC 6515 - Medical and Surgical Instruments, Equipment, and Supplies
National Item Identification Number
NIIN 002439695
Codification Country
United States
Item Name Code
INC 29491
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6515-00-243-9695
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6515-00-243-9695


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6515-00-243-9695

National Stock Number (NSN) 6515-00-243-9695, or NIIN 002439695, (catheter and needle unit,intrave) was assigned March 17, 1971 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 2 stock numbers: 6515012779372, 6515011857831.

There are 2 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 5 suppliers. Today, 4 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number is actively being procured by the US Government, with procurement history within the last 90 days. There have been 23 contracts issued for this part number, with 23 awards given. There is moderate competition for this NSN. The US Government has awarded contracts to 7 different suppliers. The last contract numbers awarded were: SPE2DS25F0132, SPE2DS25V031N, SPE2DS25V9495, SPE2DS25V9013, SPE2DS25V8415. The total value of the awarded contracts has been US$ 19,320.68.

There has been a small amount of demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 29491. [AN ITEM CONSISTING OF A CANNULATED NEEDLE WITH AN INTRAVENOUS CATHETER, AND IT MAY CONTAIN ADDITIONAL COMPONENTS, SUCH AS A HYPODERMIC SYRINGE, NEEDLE GUARD, FLOW CONTROL PLUG, AND THE LIKE. THE CATHETER IS INSERTED INTO THE VEIN BY WAY OF THE NEEDLE'S PUNCTURE, AND IS LEFT IN POSITION FOR CONTINUED INTRAVENOUS ADMINISTRATION AFTER THE NEEDLE IS WITHDRAWN. A SYRINGE, WHEN SUPPLIED, IS USED TO BETTER CONTROL INSERTION OF THE CATHETER NEEDLE UNIT OR FOR BLOOD ASPIRATION.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6515002439695 does not contain precious metals.

This NSN is associated to Schedule B 9018390030: bougies, catheters, drains and sondes and parts and accessories. The Schedule B End Use is listed as medicinal equipment. NAICS classification category 339112: surgical and medical instrument manufacturing.

This information was last updated on .


Technical Characteristics

CATHETER NOMINAL LENGTH
(ANHQ) 1.250 INCHES
CONNECTOR TYPE
(ANFJ) LUER LOCK HUB
CORE FABRICATION METHOD
(ANFS) NOT WOVEN
DESIGN DESIGNATION
(ANEH) INTRAVENOUS
FEATURES PROVIDED
(CBBL) DISPOSABLE AND STERILE AND X-RAY OPACITY
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) CATHETER & NDL UNIT D12 IV 18GAX1.25" CATH 21GAX1.25" NEEDLE 50S
MATERIAL
(MATT) PLASTIC BODY
MATERIAL
(MATT) PLASTIC POLYTETRAFLUOROETHYLENE CATHETER
MATERIAL
(MATT) STEEL CORROSION RESISTING NEEDLE
NEEDLE GUARD NOMINAL LENGTH
(ANHN) 2.500 INCHES
NEEDLE NOMINAL DIAMETER
(ANHM) 21.000 GAGE
NEEDLE NOMINAL LENGTH
(ANHP) 1.250 INCHES
NOMINAL DIAMETER
(ANHF) 18.000 GAGE
SPECIAL FEATURES
(FEAT) W/PLUG AND FEMALE LUER LOCK ADAPTER; UNIT PKG QTY 50
STYLE DESIGNATOR
(STYL) INTRAVENOUS CATHETER AND NEEDLE UNIT
SUPPLEMENTARY FEATURES
(SUPP) D-DAY ITEM FOR DOD
TIP TYPE
(ANFG) OPEN END
MATERIAL AND LOCATION
(ANNQ) PLASTIC BODY AND STEEL, CORROSION RESISTING NEEDLE AND PLASTIC, POLYTETRAFLUOROETHYLENE CATHETER
MATERIAL AND LOCATION
(ANNQ) PLASTIC BODY AND STEEL, CORROSION RESISTING NEEDLE AND PLASTIC, POLYTETRAFLUOROETHYLENE CATHETER
UNABLE TO DECODE
(ANNQ) UNABLE TO DECODE AND UNABLE TO DECODE AND UNABLE TO DECODE

Manufacturer Part Numbers

3828721

RNCC
5
RNVC
9
3828721

RNCC
5
RNVC
9
3828721

RNCC
5
RNVC
9
381144

RNCC
5
RNVC
2
381144

RNCC
3
RNVC
1

Related Inventory

10-05928
63811-4400
Condition NE
Hand Crimp Tool
Readily Available
G403811446
2/B124
Condition NE
Banded Belt, 12
Readily Available
438-11440

Condition NE
Case Constructi
Readily Available
L381144-1EA
Condition NE
1-(2-(ANILINOCA
Readily Available
63811-4400
Condition FN
HANDTOOL
Readily Available
PLT270-8-9
5320013811446
Condition NS
RIVET
Readily Available


 
Top