ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6515-00-307-0080, 6515003070080
ATOMIZER,MEDICINAL

Federal Supply Classification
FSC 6515 - Medical and Surgical Instruments, Equipment, and Supplies
National Item Identification Number
NIIN 003070080
Codification Country
United States
Item Name Code
INC 13091
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6515-00-307-0080
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6515-00-307-0080


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6515-00-307-0080

National Stock Number (NSN) 6515-00-307-0080, or NIIN 003070080, (atomizer,medicinal) was assigned January 1, 1963 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 01, 2020, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 13091. [AN ITEM USED FOR SPRAYING MEDICINAL OIL OR AQUEOUS SOLUTIONS TO THE UPPER RESPIRATORY TRACT. EXCLUDES:NEBULIZER, MEDICINAL.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6515003070080 does not contain precious metals.

This NSN is associated to Schedule B 9018908000: other instruments and appliances used in medical, surgical, dental or veterinary sciences, nesoi. The Schedule B End Use is listed as medicinal equipment. NAICS classification category 339112: surgical and medical instrument manufacturing.

This information was last updated on .


Technical Characteristics

MATERIAL AND LOCATION
(ANNQ) RUBBER, HARD CAPS-TUBING
MATERIAL AND LOCATION
(ANNQ) UNABLE TO DECODE
UNABLE TO DECODE
(AYJL) UNABLE TO DECODE
MATERIAL AND LOCATION
(ANNQ) PLASTIC RESERVOIR
MATERIAL AND LOCATION
(ANNQ) PLASTIC RESERVOIR ERR-100 ERR-100
UNIT OF ISSUE WEIGHT
(SUWT) 0.61 POUNDS
CAPACITY
(AXQD) 0.5000 OUNCES RESERVOIR
CONNECTION METHOD
(AQCF) RUBBER HOSE
DEPARTURE FROM CITED DESIGNATOR
(ZZZX) ANNQ
ENVIRONMENTAL PROTECTION
(ADZC) CHEMICAL RESISTANT
MATERIAL
(MATT) PLASTIC OR RUBBER BULB-TUBING
MATERIAL
(MATT) PLASTIC RESERVOIR
MATERIAL
(MATT) RUBBER CAPS-TUBING
NONDEFINITIVE SPEC/STD DATA
(ZZZT) 2 TYPE
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) ATOMIZER MEDICINAL PLASTIC RESERVOIR .5 OZ CAP 5" TUBE LENGTH
SHOULDERED RESERVOIR
(CCWR) NOT PROVIDED
SPECIAL FEATURES
(FEAT) FOR REPLACEMENT BULB AND TUBING,ORDER 6515-00-307-0095; FOR SPRAYING OIL AND AQUEOUS SOLUTIONS
TIP TYPE
(ANFG) RIGID
TUBE LENGTH
(AGYT) 5.000 INCHES NOMINAL
MATERIAL AND LOCATION
(ANNQ) PLASTIC BULB-TUBING ERR-100 ERR-100 OR RUBBER BULB-TUBING ERR-100 ERR-100
III PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) ATOMIZER MEDICINAL PLASTIC RESERVOIR .5 OZ CAP 5" TUBE LENGTH
UNABLE TO DECODE
(ANNQ) UNABLE TO DECODE
EXTERIOR CONTAINER WEIGHT
(ECWT) 61.00 POUNDS
EXTERIOR CONTAINER CUBIC MEASURE
(EXME) 3.00 CUBIC FEET
RESERVOIR CAPACITY
(AYJL) 0.5000 OUNCES
EXTERIOR CONTAINER QUANTITY
(EXQT) 96
UNIT OF ISSUE CUBE
(SUCB) 0.064 CUBIC FEET
INTERMEDIATE PACKAGE QUANTITY
(PKQT) 6

Manufacturer Part Numbers


Related Inventory

64NJ10
LCU5-0286-RD_10X
Condition NE
Hard Hat Notic
Readily Available
64NJ11
LCU5-0286-RD_14X
Condition NE
Hard Hat Notic
Readily Available
64NJ12
LCU5-0286-RD_5X3
Condition NE
Hard Hat Notic
Readily Available
64NJ13
LCU5-0286-RD_7X5
Condition NE
Hard Hat Notic
Readily Available
62UH83
LCU4-0286-RD_10X
Condition NE
Hard Hat Dange
Readily Available
62UH84
LCU4-0286-RD_14X
Condition NE
Hard Hat Dange
Readily Available
62UH85
LCU4-0286-RD_5X3
Condition NE
Hard Hat Dange
Readily Available
62UH86
LCU4-0286-RD_7X5
Condition NE
Hard Hat Dange
Readily Available
35JP02
U4-1286-RD_10X7
Condition NE
Caution Sign: R
Readily Available
35JP03
U4-1286-RD_14X10
Condition NE
Caution Sign: R
Readily Available
35JP04
U4-1286-RD_7X5
Condition NE
Caution Sign: R
Readily Available


 
Top