ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6515-00-487-9782, 6515004879782
NEEDLE,BIOPSY

Federal Supply Classification
FSC 6515 - Medical and Surgical Instruments, Equipment, and Supplies
National Item Identification Number
NIIN 004879782
Codification Country
United States
Item Name Code
INC 22456
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6515-00-487-9782
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6515-00-487-9782


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6515-00-487-9782

National Stock Number (NSN) 6515-00-487-9782, or NIIN 004879782, (needle,biopsy) was assigned June 6, 1969 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 22456. [AN ITEM USED ON THE LIVING BODY TO REMOVE TISSUE, CELLS, OR FLUIDS FOR DIAGNOSIS.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6515004879782 does not contain precious metals.

This NSN is associated to Schedule B 9018320000: tubular metal needles and needles for sutures and parts and accessories thereof. The Schedule B End Use is listed as medicinal equipment. NAICS classification category 339112: surgical and medical instrument manufacturing.

This information was last updated on .


Technical Characteristics

MATERIAL AND LOCATION
(ANNQ) PLASTIC HUB STEEL, FED STD 66, AISI 304/SAE 30304 CANNULA
MATERIAL AND LOCATION
(ANNQ) PLASTIC SHEATH ERR-100 ERR-100
UNABLE TO DECODE
(ASWZ) UNABLE TO DECODE
CANNULA WALL THICKNESS DESIGNATION
(ANNN) REGULAR
DESIGN DESIGNATION
(ANEH) PROSTATIC
FEATURES PROVIDED
(CBBL) STERILE
MATERIAL DOCUMENT AND CLASSIFICATION
(MDCL) FED STD 66 FED STD SINGLE MATERIAL RESPONSE AND AISI 304 ASSN STD SINGLE MATERIAL RESPONSE AND SAE 30304 ASSN STD SINGLE MATERIAL RESPONSE CANNULA
MATERIAL
(MATT) PLASTIC HUB
MATERIAL
(MATT) PLASTIC OBTURATOR KNOB
MATERIAL
(MATT) PLASTIC SHEATH
MATERIAL
(MATT) STEEL COMP 304 CANNULA
MATERIAL
(MATT) STEEL COMP 304 OBTURATOR ROD
NEEDLE CANNULA GAGE DESIGNATION AND LOCATION
(ANNS) 14 GAGE CANNULA
NONDEFINITIVE SPEC/STD DATA
(ZZZT) 1 SIZE
SPECIAL FEATURES
(FEAT) CANNULA EXTENDS 4.500 IN.BEYOND THE END OF HUB,20 MM LG SPECIMEN RETAINING NOTCH,DISPOSABLE,UNIT QTY 1; SECURITY STOP NOT INCLUDED
MATERIAL AND LOCATION
(ANNQ) PLASTIC HUB
EXTERIOR CONTAINER QUANTITY
(EXQT) 72
UNIT OF ISSUE WEIGHT
(SUWT) 0.13 POUNDS
MATERIAL AND LOCATION
(ANNQ) STEEL, FED STD 66, AISI 304/SAE 30304 CANNULA AND PLASTIC HUB AND PLASTIC OBTURATOR KNOB AND STEEL, FED STD 66, AISI 304/SAE 30304 OBTURATOR ROD AND PLASTIC SHEATH
STERILITY
(AKMX) STERILE
MATERIAL AND LOCATION
(ANNQ) PLASTIC HUB ERR-100 ERR-100
SECURITY STOP
(ASWZ) NOT INCLUDED
EXTERIOR CONTAINER CUBIC MEASURE
(EXME) 2.001 CUBIC FEET
UNABLE TO DECODE
(AKMX) UNABLE TO DECODE
MATERIAL AND LOCATION
(ANNQ) PLASTIC SHEATH
MATERIAL AND LOCATION
(ANNQ) PLASTIC SHEATH STEEL, FED STD 66, AISI 304/SAE 30304 OBTURATOR ROD
UNABLE TO DECODE
(ANNQ) UNABLE TO DECODE AND UNABLE TO DECODE AND UNABLE TO DECODE AND UNABLE TO DECODE AND UNABLE TO DECODE
INTERMEDIATE PACKAGE QUANTITY
(PKQT) 12
MATERIAL AND LOCATION
(ANNQ) PLASTIC OBTURATOR KNOB PLASTIC HUB
EXTERIOR CONTAINER WEIGHT
(ECWT) 3.00 POUNDS
UNIT OF ISSUE CUBE
(SUCB) 0.019 CUBIC FEET

Manufacturer Part Numbers


Related Inventory



 
Top