ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6515-00-990-1971, 6515009901971
THERMOMETER,CLINICAL,HUMAN

Federal Supply Classification
FSC 6515 - Medical and Surgical Instruments, Equipment, and Supplies
National Item Identification Number
NIIN 009901971
Codification Country
United States
Item Name Code
INC 14960
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6515-00-990-1971
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6515-00-990-1971


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6515-00-990-1971

National Stock Number (NSN) 6515-00-990-1971, or NIIN 009901971, (thermometer,clinical,human) was assigned November 15, 1978 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, there are no suppliers listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 02, 1991, this NSN's acquisition method was noted as: Not established. Not established.

This NSN is assigned to Item Name Code (INC) 14960. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6515009901971 does not contain precious metals.

This NSN is associated to Schedule B 9018908000: other instruments and appliances used in medical, surgical, dental or veterinary sciences, nesoi. The Schedule B End Use is listed as medicinal equipment. NAICS classification category 339112: surgical and medical instrument manufacturing.

This information was last updated on .


Technical Characteristics

SCALE MEASUREMENT RANGE
(CSYG) +96.000/+106.000 DEG FAHRENHEIT
III SCALE MEASUREMENT RANGE
(CSYG) +96.000 TO 106.000 DEG FAHRENHEIT
DESIGN TYPE
(APGF) RECTAL
MATERIAL
(MATT) GLASS BULB
MATERIAL
(MATT) GLASS STEM, LIQUID IN GLASS
NONDEFINITIVE SPEC/STD DATA
(ZZZT) 2 TYPE AND E CLASS
SCALE INSCRIPTION/BACKGROUND COLOR
(BGKZ) DARK MARKING ON WHITE BACKGROUND
SCALE MEASUREMENT RANGE
(CSYG) +96.000 TO 106.000 DEG FAHRENHEIT
SCALE TYPE
(ATEQ) GLASS FUSED STEM
SPECIAL FEATURES
(FEAT) REUSABLE; NONSTERILE; TRIANGULAR MAGNIFYING STEM; PERMANENT BAKED AND ANNEALED MARKINGS; WITH SMALL RED BALL PERMANENTLY ATTACHED TO TOP; NORMAL TEMPERATURE MARKED
UNIT TYPE
(APQB) MERCURY

Manufacturer Part Numbers


Related Inventory



 