ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6515-01-209-1174, 6515012091174
Cancelled -> Replaced by 6515010093016

Federal Supply Classification
FSC 6515 - Medical and Surgical Instruments, Equipment, and Supplies
National Item Identification Number
NIIN 012091174
Codification Country
United States
Item Name Code
INC 29491
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6515-01-209-1174
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6515-01-209-1174


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6515-01-209-1174

National Stock Number (NSN) 6515-01-209-1174, or NIIN 012091174, (catheter and needle unit,intrave) was assigned May 24, 1985 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 6515010093016.

There are 3 manufacturer part numbers associated with this NSN. 2 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 4 suppliers. Today, 4 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years, with the most recent procurement date of Dec 11, 2012. There have been 7 contracts issued for this part number, with 8 awards given. There is minimal competition for this NSN. The US Government has awarded contracts to 4 different suppliers. The last contract numbers awarded were: SPM2DS13MD654, SPM2DS13MD654, SPM2DS13MD113, SPM20005D6180, SPM20005D6180. The total value of the awarded contracts has been US$ 14,687.40.

There has been a small amount of demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 29491. [AN ITEM CONSISTING OF A CANNULATED NEEDLE WITH AN INTRAVENOUS CATHETER, AND IT MAY CONTAIN ADDITIONAL COMPONENTS, SUCH AS A HYPODERMIC SYRINGE, NEEDLE GUARD, FLOW CONTROL PLUG, AND THE LIKE. THE CATHETER IS INSERTED INTO THE VEIN BY WAY OF THE NEEDLE'S PUNCTURE, AND IS LEFT IN POSITION FOR CONTINUED INTRAVENOUS ADMINISTRATION AFTER THE NEEDLE IS WITHDRAWN. A SYRINGE, WHEN SUPPLIED, IS USED TO BETTER CONTROL INSERTION OF THE CATHETER NEEDLE UNIT OR FOR BLOOD ASPIRATION.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6515012091174 does not contain precious metals.

This NSN is associated to Schedule B 9018390030: bougies, catheters, drains and sondes and parts and accessories. The Schedule B End Use is listed as medicinal equipment. NAICS classification category 339112: surgical and medical instrument manufacturing.

This information was last updated on .


Technical Characteristics

UNABLE TO DECODE
(ANNQ) UNABLE TO DECODE
MATERIAL AND LOCATION
(ANNQ) STEEL, CORROSION RESISTING NEEDLE
CONNECTOR TYPE
(ANFJ) LUER LOCK HUB
CORE FABRICATION METHOD
(ANFS) NOT WOVEN
DESIGN DESIGNATION
(ANEH) INTRAVENOUS
FEATURES PROVIDED
(CBBL) DISPOSABLE AND STERILE
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) CATHETER & NEEDLE UNIT IV 16GA RADIOPAQUE 12" CATH STER DISP 50S
MATERIAL
(MATT) STEEL CORROSION RESISTING NEEDLE
NEEDLE NOMINAL LENGTH
(ANHP) 2.500 INCHES
NEEDLE GUARD NOMINAL LENGTH
(ANHN) 2.500 INCHES
NEEDLE NOMINAL DIAMETER
(ANHM) 14.0 GAGE
NOMINAL DIAMETER
(ANHF) 16.0 GAGE
SPECIAL FEATURES
(FEAT) A PLASTIC PROTECTIVE CONDUIT ENCLOSE THE CATHETER UP TO THE NEEDLE HUB; 12 INCHES LONG CATHETER; INDIVIDUALLY PACKAGED; RADIOPAQUE; UNIT QTY 50
STYLE DESIGNATOR
(STYL) INTRAVENOUS CATHETER AND NEEDLE UNIT
SUPPLEMENTARY FEATURES
(SUPP) D-DAY ITEM FOR DOD
TIP TYPE
(ANFG) BEVELED

Manufacturer Part Numbers


Related Inventory

7738-4903

Condition NE
Gradall Cap Ove
Readily Available
53EH03
K0338.4903
Condition NE
Indexing Plunge
Readily Available
53EH04
K0338.4903AJ
Condition NE
Indexing Plunge
Readily Available
7671CNAS42DD6-28FC
5365-01-438-4903
Condition NE
SPACER
Readily Available
B384903
Condition FN
Readily Available
01-90-2295
4820013849033
Condition NS
PARTS KIT
Readily Available
12384903
2590-01-446-3497
Request
12384903
2590 01 446 3497
HANDRAIL,VEHICU
Request


 
Top