ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6520-01-047-0646, 6520010470646
PROBE,PERIODONTAL

Federal Supply Classification
FSC 6520 - Dental Instruments, Equipment, and Supplies
National Item Identification Number
NIIN 010470646
Codification Country
United States
Item Name Code
INC 27516
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: We have 2 qualified suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6520-01-047-0646
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6520-01-047-0646


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6520-01-047-0646

National Stock Number (NSN) 6520-01-047-0646, or NIIN 010470646, (probe,periodontal) was assigned August 29, 1977 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. 2 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 4 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts. ISO Group has several sources of supply for this NSN.

This part number has not been procured by the US Government in over 5 years.

There has been very little demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 27516. [AN INSTRUMENT USED IN DETERMINING THE EXISTENCE OF PERIODONTAL POCKETS AND MAY BE GRADUATED TO MEASURE THE DEPTH OF PERIODONTAL POCKETS.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 6520010470646 does not contain precious metals.

This NSN is associated to Schedule B 9018490000: other instruments and appliances, used in dental sciences; and parts and accessories, except dental drill engines, nesoi. The Schedule B End Use is listed as medicinal equipment. NAICS classification category 339114: dental equipment and supplies manufacturing.

This information was last updated on .


Technical Characteristics

PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) PROBE PERIODONTAL CRES BLADE BRASS HANDLE GRADUATED 3 6 9 & 12MM
SPECIAL FEATURES
(FEAT) CALIBRATED IN 3 MM,6 MM,9 MM AND 12 MM INCREMENTS; COLOR CODED
UNABLE TO DECODE
(ANNQ) UNABLE TO DECODE
UNABLE TO DECODE
(ANNR) UNABLE TO DECODE
UNIT TYPE
(APQB) GRADUATED
SURFACE TREATMENT AND LOCATION
(ANNR) PASSIVATED BLADE
SURFACE TREATMENT AND LOCATION
(ANNR) PASSIVATED BLADE ERR-100 ERR-100
MATERIAL AND LOCATION
(ANNQ) STEEL, CORROSION RESISTING BLADE
SURFACE TREATMENT AND LOCATION
(ANNR) CHROMIUM PLATED HANDLE ERR-100 ERR-100 OR NICKEL PLATED HANDLE ERR-100 ERR-100
UNIT OF ISSUE WEIGHT
(SUWT) 0.04 POUNDS
MATERIAL AND LOCATION
(ANNQ) BRASS HANDLE
III PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) PROBE PERIODONTAL CRES BLADE BRASS HANDLE GRADUATED 3 6 9 & 12MM
SURFACE TREATMENT AND LOCATION
(ANNR) UNABLE TO DECODE
UNIT OF ISSUE CUBE
(SUCB) 0.001 CUBIC FEET
MATERIAL AND LOCATION
(ANNQ) BRASS HANDLE ERR-100 ERR-100

Manufacturer Part Numbers


Related Inventory

G600538979
HUMID43-PLAT
Condition NE
Aroma Cl-Mist H
Readily Available
G600538955
PL14856
Condition NE
Clip Glazing Sa
Readily Available
G0478956
WWG-DISP-CP1200
Condition NE
Cotter Pin Asst
Readily Available
2WZU8
WWG-DISP-CP1200
Condition NE
Pin Assortment,
Readily Available
600-5389
6520010470646
Condition NS
PROBE
Readily Available
HLT712KM-08-20
Condition NE
HI-LOK HI-TIGUE
Readily Available
BACB30NE4H5
5306005389070
Condition NS
BOLT
Readily Available
RM21WTP-CP12(71)
Condition FN
Readily Available
J644P04D
5306005389046
Condition NS
BOLT
Readily Available


 