NSN 6525-01-159-3009, 6525011593009
X-RAY APPARATUS,RADIOGRAPHIC,MEDICAL

Federal Supply Classification
FSC 6525 - Imaging Equipment and Supplies: Medical, Dental, Veterinary
National Item Identification Number
NIIN 011593009
Codification Country
United States
Item Name Code
INC 06320
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6525-01-159-3009
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6525-01-159-3009


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6525-01-159-3009

National Stock Number (NSN) 6525-01-159-3009, or NIIN 011593009, (x-ray apparatus,radiographic,medical) was assigned August 5, 1983 in the Federal Logistics Information System (FLIS). This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 01, 2020, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 06320. [A PORTABLE, MOBILE, OR STATIONARY DEVICE USUALLY CONSISTING OF AN X-RAY TUBE, TRANSFORMER, CONTROL, AND ASSOCIATED DEVICES DESIGNED FOR RADIOGRAPHIC EXAMINATION OF PATIENTS.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 6525011593009 does not contain precious metals.

This information was last updated on .


Technical Characteristics

RADIOGRAPHIC TIMER TYPE
(CLPX) EXPOSURE
FREQUENCY IN HERTZ
(FREQ) 50.0 OR 60.0
ERR DEFAULT
(CLPY) ERR DEFAULT
DESIGN TYPE
(APGF) MOBILE
MOUNTING TYPE
(AAXX) MOBILE
TUBE COOLING METHOD
(CLPG) AIR
OPERATION METHOD
(APHE) MANUAL
TUBE STAND MOUNTING TYPE
(CLPR) BASE
III DESIGN TYPE
(APGF) MOBILE
TUBE QUANTITY
(ARNF) 1
VOLTAGE IN VOLTS
(ELEC) 115.0 AND 230.0
TUBE MOUNTING TYPE
(CLPH) TUBE STAND
CONTROL TYPE
(AQZF) CABINET
TRANSFORMER OUTPUT CAPACITY
(CLQF) 200 MA AT 100 KV PEAK; 200 MA AT 100 KV PEAK; 300 MA AT 50/190 KV PEAK
TUBE TYPE
(AWGH) DOUBLE FOCUS, ROTATING ANODE RADIOGRAPHIC
RECTIFICATION TYPE
(BPKZ) FULL-WAVE
TRANSFORMER RECTIFICATION METHOD
(CLQD) BRIDGE W/SILICONE RECTIFIER
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) XRAY APPARATUS RADIOGRAPHIC MEDICAL MOBILE300MA110PKV1TUBE BATTR
FLUOROSCOPIC TIMER TYPE
(CLPY) NOT PROVIDED
SPECIAL FEATURES
(FEAT) DEAD MAN BRAKE; TUBE HEAD,COUNTERBALANCED; TUBE,MAX CAPACITY 110000 HEAT UNITS; SELF PROPELLED; BATTERY POWERED