ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6525-01-312-6411, 6525013126411
X-RAY APPARATUS,RADIOGRAPHIC AND FLUOROSCOPIC

Federal Supply Classification
FSC 6525 - Imaging Equipment and Supplies: Medical, Dental, Veterinary
National Item Identification Number
NIIN 013126411
Codification Country
United States
Item Name Code
INC 06321
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6525-01-312-6411
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6525-01-312-6411


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6525-01-312-6411

National Stock Number (NSN) 6525-01-312-6411, or NIIN 013126411, (x-ray apparatus,radiographic and fluoroscopic) was assigned December 21, 1989 in the Federal Logistics Information System (FLIS). NIIN 013126411 was cancelled on February 2, 2014, with a cancelled status of "Item is Cancelled WITHOUT Replacement." There is no known replacement specified for this stock number. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, there are no suppliers listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 01, 2020, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 06321. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 6525013126411 does not contain precious metals.

This information was last updated on .


Technical Characteristics

DRIVE TYPE
(AKCV) MOTOR
ERR DEFAULT
(CLPT) ERR DEFAULT
TUBE STAND MOUNTING TYPE
(CLPR) FLOOR TO CEILING
BUCKY DIAPHRAGM
(CLPW) INCLUDED
TRANSFORMER OUTPUT CAPACITY
(CLQF) TO 300 MA AT 150 KV PEAK
TABLE TYPE
(BNBB) TILTING
TRANSFORMER RECTIFICATION METHOD
(CLQD) SELF-RECTIFYING
TUBE MOUNTING TYPE
(CLPH) TABLE AND TUBE STAND
TILT RANGE
(CLPT) 90 DEG VERTICAL AND 15 DEG TRENDLEBERG
DESIGN TYPE
(APGF) STATIONARY
ELECTRIC POWER RATING
(ARQE) 45000.0 WATTS NOMINAL
TUBE COOLING METHOD
(CLPG) AIR
PHASE
(FAAZ) SINGLE
RECTIFICATION TYPE
(BPKZ) FULL-WAVE
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) X-RAY APPARATUS: HIGH CAPACITY RADIOGRAPHIC AND FLUROSCOPIC
VOLTAGE IN VOLTS
(ELEC) 190.05 AND 270.0
ACCESSORY COMPONENTS AND QUANTITY
(AKYD) ADJ NON-SKID FOOTREST-1; COMPRESSION-IMMOBILIZING DEVICE-1; HEAD CLAMP-1; PATIENT GRASP HANDLES-1PR; SKIDPROOF PATIENT STEP-1; SHOULDER REST-1
TUBE QUANTITY
(ARNF) 2
ERR DEFAULT
(CLPW) ERR DEFAULT
SPECIAL FEATURES
(FEAT) 50/60 HZ,AC; W/ROTATING ANODE; DESIGNED FOR USE W/IMAGE INTENSIFIER; C/O SOLID STATE CONTROL UNIT,TRANSFORMER W/SOLID STATE RECITIFIERS; 45 FT RADIOGRAPHIC AND 25 FT FLUOROSCOPIC HIGH VOLTAGE CABLES; COLLIMATOR,24 BY 24 CM FRONT END-LOADING,SPOT-FILM DEVICE; BUCKY DIAPHRAGM,FLOOR-TO CEILING FLOOR MT,AND VERT CASSETTE HOLDER

Manufacturer Part Numbers


Related Inventory



 
Top