ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6525-01-519-6563, 6525015196563
X-RAY APPARATUS,RADIOGRAPHIC,MED

Federal Supply Classification
FSC 6525 - Imaging Equipment and Supplies: Medical, Dental, Veterinary
National Item Identification Number
NIIN 015196563
Codification Country
United States
Item Name Code
INC 06320
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6525-01-519-6563
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6525-01-519-6563


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6525-01-519-6563

National Stock Number (NSN) 6525-01-519-6563, or NIIN 015196563, (x-ray apparatus,radiographic,med) was assigned April 27, 2004 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 4 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Dec 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 06320. [A PORTABLE, MOBILE, OR STATIONARY DEVICE USUALLY CONSISTING OF AN X-RAY TUBE, TRANSFORMER, CONTROL, AND ASSOCIATED DEVICES DESIGNED FOR RADIOGRAPHIC EXAMINATION OF PATIENTS.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 6525015196563 does not contain precious metals.

This NSN is associated to Schedule B 9022140000: apparatus based on the use of x-rays for medical, surgical, or veterinary uses, nesoi. The Schedule B End Use is listed as medicinal equipment. NAICS classification category 334517: irradiation apparatus manufacturing.

This information was last updated on .


Technical Characteristics

DESIGN TYPE
(APGF) MOBILE
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) OEC MINIVIEW 6800 C-ARM MOBILE DIGITAL 19 IN. DIAGONAL DUAL MONITORS
SPECIAL FEATURES
(FEAT) 50 MICRON FOCAL SPOT CAPTURES THE FINEST ANATOMICAL DETAIL; IMMEDIATE RESULTS-FULLY DIGITAL 1K X 1K, 16-BIT IMAGE PROCESSING W/REAL TIME EDGE ENHANCEMENT; 19 IN. DIAGONAL DUAL MONITORS; ADVANCED DIGITAL IMAGE PROCESSING AIDS PATIENT ANNOTATION, ARCHIVE AND REVIEW; UP TO 400 IMAGES SAVED IN MEMORY OR TO REMOVABLE MEDIA, SENT TO DICOM SERVERS OR PRINTED; DESIGNED FOR SIMPLE EXTREMITY IMAGING;LINE OF SITE CONTROLS FOR PHYSICIAN ON EITHER SIDE OF THE TUBE HEAD EASILY REACHED BY OPERATOR FROM WITHIN STERILE FIELD; COMPACT DESIGN-5 SQ. FT OF FLOOR SPACE; SIMPLE SETUP-ONE BUTTON TURN ON AUTOMATICALLY SETS OPTIMUM IMAGING PARAMETERS; EASY PATIENT POSITIONING, 220 DEG LATERAL OR OBLIQUE ROTATION, 115 DEG ORBITAL ROTATION, 25 DEG OVERSCAN; FREELY ADJUSTS OVER A 28 IN. VERTICAL MOVEMENT TO ACCOMMODATE AN OR TABLE HEIGHT OR STANDING PROCEDURES; MAKES IT EASY TO OBTAIN, STORE AND PRINT HIGH QUALITY FLORO IMAGES
III DESIGN TYPE
(APGF) MOBILE

Manufacturer Part Numbers


Related Inventory

69B04049-1
Condition FN
NUT 2691
Readily Available
G0404914
DSMM500
Condition NE
Digital Soil Mo
Readily Available
G704049135
0137Q
Condition NE
Safer Gro 0137Q
Readily Available
G9040491
840263
Condition NE
Dust Sock, For
Readily Available
624040-4-0491

Condition NE
Aeroquip 303/30
Readily Available
624000-4-0491

Condition NE
Aeroquip 303/30
Readily Available
M666000-4-0491

Condition NE
Aeroquip 666/66
Readily Available
T666320-4-0491

Condition NE
Aeroquip 666/66
Readily Available
M666300-4-0491

Condition NE
Aeroquip 666/66
Readily Available
JAN1N5615
5961004049136
Condition NS
SEMICONDUCTOR
Readily Available
106135-57
4720010404917
Condition NS
HOSE ASSY
Readily Available


 
Top