ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6525-01-607-0089, 6525016070089
PROBE,RADIATION,X-RAY SYSTEM CALIBRATOR SET

Federal Supply Classification
FSC 6525 - Imaging Equipment and Supplies: Medical, Dental, Veterinary
National Item Identification Number
NIIN 016070089
Codification Country
United States
Item Name Code
INC 41726
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6525-01-607-0089
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6525-01-607-0089


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6525-01-607-0089

National Stock Number (NSN) 6525-01-607-0089, or NIIN 016070089, (probe,radiation,x-ray system calibrator set) was assigned May 29, 2012 in the Federal Logistics Information System (FLIS). NIIN 016070089 was cancelled on December 2, 2019, with a cancelled status of "Item is Cancelled WITHOUT Replacement." There is no known replacement specified for this stock number. This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years, with the most recent procurement date of Aug 01, 2019. There have been 7 contracts issued for this part number, with 7 awards given. There is minimal competition for this NSN. The US Government has awarded contracts to 2 different suppliers. The last contract numbers awarded were: SPE2DH19P2249, SPE2DH17P0400, SPE2DH17P0307, SPE2DH16M2651, SPE2D114M0257. The total value of the awarded contracts has been US$ 78,137.06.

There has been a small amount of demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Sep 20, 2020, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 41726. [AN ITEM WHICH, WHEN INTERFACED WITH A CALIBRATOR SET, X-RAY SYSTEM, AFFORDS NON-INVASIVE COMPLIANCE TESTING CAPABILITIES IN ACCORDANCE WITH REGULATION GOVERNING STATIONARY RADIOGRAPHIC AND FLUOROSCOPIC X-RAY SYSTEMS. IT FUNCTIONS AS A TRANSDUCER FOR MEASURING THE RADIATION OUTPUT OF X-RAY EXPOSURES. IT IS USED PRIMARILY TO DETERMINE TABLETOP ABSOLUTE VALUES, REPEATABILITY OF BEAM OUTPUT, AND HALF VALUE LAYERS.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 6525016070089 does not contain precious metals.

This information was last updated on .


Technical Characteristics

PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) PROBE MAS-3
UNABLE TO DECODE
(FEAT) UNABLE TO DECODE
UNABLE TO DECODE
(CXCY) UNABLE TO DECODE
SPECIAL FEATURES
(FEAT) NON-INVASIVE MA AND MAS PROBE FOR PIRANHA; MEASURING RANGE: 0.1-2000 MA, 0.0001-9999 MAS; 4 METER CABLE


Related Inventory

2.3221941311e+011
Readily Available
2.3221941363e+011
Readily Available
2322-194-13479
Readily Available
4500-521-9413-50
Readily Available
2322-194-13189
Readily Available
2.3221941323e+011
Readily Available
2.3221941392e+011
Readily Available
2.3221941357e+011
Readily Available
2.3221941333e+011
Readily Available
2.3221941336e+011
Readily Available
2.3221941339e+011
Readily Available
2.3221941356e+011
Readily Available
2322-194-13304
Readily Available
2.3221941316e+011
Readily Available
2.3221941334e+011
Readily Available
2.3221941362e+011
Readily Available
2.3221941313e+011
Readily Available
2.3221941347e+011
Readily Available
2.3221941348e+011
Readily Available
2.3221941382e+011
Readily Available
2322-194-13159
Readily Available
2322-194-13128
Readily Available
2322-194-13153
Readily Available
2322-194-13331
Readily Available
2322-194-13751
Readily Available
2.3221941312e+011
Readily Available
2.3221941314e+011
Readily Available
2.3221941317e+011
Readily Available
2.3221941327e+011
Readily Available
2.322194133e+011
Readily Available
2.3221941343e+011
Readily Available
2.3221941368e+011
Readily Available
2.3221941369e+011
Readily Available
2.3221941375e+011
Readily Available
2.3221941376e+011
Readily Available
2.3221941391e+011
Readily Available
G202194139
102199-022
Condition NE
OJ2199 M RD Ril
Readily Available
2322-194-13563
Readily Available
7671CMS51021-106
5305-01-219-4137
Condition NE
SETSCREW
Readily Available
B1821BH031C150L
5306-01-219-4131
Bolt
Readily Available
3120-00-472-1941
004721941.3120
Condition NS
BEARING THRUST
Readily Available
2132620-1
4730005219413
Condition NS
HALF COUPLING
Readily Available


 