NSN 6630-01-314-4292, 6630013144292
ANALYZER,BLOOD GAS

Federal Supply Classification
FSC 6630 - Chemical Analysis Instruments
National Item Identification Number
NIIN 013144292
Codification Country
United States
Item Name Code
INC 38049
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6630-01-314-4292
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6630-01-314-4292


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6630-01-314-4292

National Stock Number (NSN) 6630-01-314-4292, or NIIN 013144292, (analyzer,blood gas) was assigned January 30, 1990 in the Federal Logistics Information System (FLIS). NIIN 013144292 was cancelled on May 2, 2014, with a cancelled status of "Item is Cancelled WITHOUT Replacement." There is no known replacement specified for this stock number. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jan 09, 2020, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 38049. [AN INSTRUMENT DESIGNED FOR DETERMINATION OF THE CARBON DIOXIDE COMBINING POWER, OXYGEN, CARBON MONOXIDE AND NITROGEN OF WHOLE BLOOD OR BLOOD PLASMA. MAY ALSO BE USED FOR MICRO DETERMINATIONS OF GAS OTHER THAN BLOOD GASES, DEVELOPED FROM SOLUTIONS, SUCH AS ORGANIC NITROGEN AND CARBON, UREA, AMINO NITROGEN, IODATES, SULPHATES, SUGAR, CALCIUM LACTIC ACID, POTASSIUM, AND ANALYSIS OF GAS MIXTURES.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6630013144292 does not contain precious metals.

This information was last updated on .


Technical Characteristics

CURRENT TYPE
(ACDC) AC
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) ANALYZER BLOOD GAS VOLUMETRIC 115/230V 50/60HZ SINGLE PHASE AUTO
SUPPLEMENTARY FEATURES
(SUPP) XCENTRAL PROCUREMENT OF MEDICAL EQUIPMENT "CENPROME" SERVICE CONTROLLED AND MANAGED ITEM; REQUISITION USING PUBLISHED CUSTOMER ORDER LIST (COL) ONLY IN ACCORDANCE W/SERVICE OR AGENCY INSTRUCTIONS; SERVICE POINTS OF CONTACT FOR INFORMATION AND REQUISITIONING INSTRUCTIONS ARE: U.S. ARMY MEDICAL MATERIEL AGENCY,USAMMA/SGMMA-OM,FT. DETRICK,MD 21702-5001,AV 343-7403 COMMERCIAL (301) 619-7403; AIR FORCE MEDICAL LOGISTICS OFFICE,AFMLO/FOM,FT. DETRICK MD 21702-5001,AV 343-7487 COMMERCIAL (301) 619-7487; NAVAL MEDICAL MATERIEL SUPPORT COMMAND,NAVMEDMAT SUPPCOM,FT. DETRICK MD 21702-5001,AV 343-7117 COMMERCIAL (301) 619-7117; REQUISITIONER SHOULD SPECIFY THE VOLTAGE AND FREQUENCY REQUIRED; 115 VAC,60 HZ,115 VAC,50 HZ; 230 VAC,50 HZ,230 VAC,60 HZ
VOLTAGE IN VOLTS
(ELEC) 115.0 AND 230.0
SPECIAL FEATURES
(FEAT) AUTOMATIC; C/O ELECTRODES,REAGENTS,INITIAL CALIBRATION AND SUPPLIES NECESSARY FOR START UP OPERATION; CALCULATES AND MEASURES PH,PO2 AND BASE EXCESS; BICARBONATE AND 02 SATURATION; PERMITS THE INTRODUCTION OF SAMPLES OF VENOUS BLOOD,ARTERIAL BLOOD AND EXPIRED GAS
FREQUENCY RATING
(ACZB) 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
SPECIFICATION/STANDARD DATA
(ZZZK) 51404-DLA120-92-D-8084 GOVERNMENT SPECIFICATION