NSN 6630-01-481-6145, 6630014816145
ANALYZER MODULE,CLINICAL CHEMIST

Federal Supply Classification
FSC 6630 - Chemical Analysis Instruments
National Item Identification Number
NIIN 014816145
Codification Country
United States
Item Name Code
INC 41370
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6630-01-481-6145
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6630-01-481-6145


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6630-01-481-6145

National Stock Number (NSN) 6630-01-481-6145, or NIIN 014816145, (analyzer module,clinical chemist) was assigned January 17, 2001 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 41370. [A UNIT WHICH INTERFACES WITH THE AUTOMATED ANALYZER. USED TO PROVIDE ADDITIONAL TEST RESULTS TO AID DIAGONSIS.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6630014816145 does not contain precious metals.

This NSN is associated to Schedule B 9027803200: chemical analysis instruments and apparatus, nesoi. The Schedule B End Use is listed as laboratory testing instruments. NAICS classification category 334516: analytical laboratory instrument manufacturing.

This information was last updated on .


Technical Characteristics

UNIT OF ISSUE WEIGHT
(SUWT) 35.00 POUNDS
III METHOD OF ANALYSIS
(CYFV) PHOTOMETRIC
CURRENT TYPE
(ACDC) AC
DEPTH
(DPTH) 18.000 INCHES
DETECTOR TYPE
(APYE) PHOTODIODE
FREQUENCY RATING
(ACZB) 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL
HEIGHT
(ABRN) 9.500 INCHES
METHOD OF ANALYSIS
(CYFV) PHOTOMETRIC
SPECIAL FEATURES
(FEAT) TWO CHANNEL INPEDANCE SYSTEM, OPTICAL SYSTEM AND LUMINESCENCE SYSTEM; TWO PRECIOUS METAL WIRES; USES CUVETTE S P/N 367 TO HOLD BLOOD FOR TESTING
TEST SAMPLE/SPECIMEN SIZE
(CYFZ) 450 MICROLITERS OF BLOOD, 450 MICROLITERS OF SALINE AND 100 MICROLITERS CHRONO-LUME REAGENT FOR A TOTAL OF 1 ML.
TEST SAMPLE/SPECIMEN TYPE
(CYHM) WHOLE BLOOD
TEST TYPE FOR WHICH DESIGNED
(AQXY) TESTS PLATELET AGGREGATION
VOLTAGE IN VOLTS
(ELEC) 115.0 OR 230.0
WAVELENGTH RANGE DATA NON-AVAILABILITY
(CYFW) NOT OBTAINABLE FROM THE MANUFACTURER
WIDTH
(WDTH) 18.250 INCHES
ERR DEFAULT
(CYFW) ERR DEFAULT