NSN 6630-01-672-8480, 6630016728480
ANALYZER,CONTAMINENT

Federal Supply Classification
FSC 6630 - Chemical Analysis Instruments
National Item Identification Number
NIIN 016728480
Codification Country
United States
Item Name Code
INC 77777
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: We have 3 qualified suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6630-01-672-8480
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6630-01-672-8480


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6630-01-672-8480

National Stock Number (NSN) 6630-01-672-8480, or NIIN 016728480, (analyzer,contaminent) was assigned May 18, 2018 in the Federal Logistics Information System (FLIS). This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts. ISO Group has several sources of supply for this NSN.

This part number has not been procured by the US Government in over a year. There have been 2 contracts issued for this part number, with 2 awards given. There is minimal competition for this NSN. The US Government has awarded contracts to 2 different suppliers. The last contract numbers awarded were: SPE2DH22V1068, SPE2DH22P0353. The total value of the awarded contracts has been US$ 224,050.00.

There has been very little demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on May 24, 2018, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 77777. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6630016728480 does not contain precious metals.

This information was last updated on .


Technical Characteristics

SPECIAL FEATURES
(FEAT) USES MSD S MULTI-ARRAY ELECTROCHEMILUMINESCENCE (ECL) TECHNOLOGY TO CARRY OUT HIGHLY SENSITIVE, MULTIPLEXED IMMUNOASSAYS FOR BIOTHREAT AGENTS; THE PR2 WORKS WITH 96-WELL ASSAY PLATES; EACH WELL OF THE PLATE HAS AN ARRAY OF UP TO 25 DIFFERENT ANTIBODIES TO ENABLE MULTIPLE TARGETS, LIKE BACTERIA, VIRUSES AND TOXINS, TO BE MEASURED SIMULTANEOUSLY; THE PR2 CAN BE USED TO TEST A WIDE VARIETY OF SAMPLE TYPES INCLUDING MANY CLINICAL MATRICES, DRY FILTER UNIT EXTRACTS AEROSOL, FOOD, BEVERAGE, WATER, AND SOIL SAMPLES; MSD HAS OVER 30 ASSAYS FOR BIOTHREAT AGENTS INCLUDING TOXIN, BACTERIAL, AND VIRAL TARGETS; NEW ASSAYS CAN BE ADDED TO EXISTING KITS/PANELS TO ADDRESS NEW THREATS OR ENTIRELY NEW PANELS CAN BE DEVELOPED TO MEET NEW DEMANDS; TIME TO RESULTS VARY FROM 15 MINUTES TO 60 MINUTES DEPENDING ON APPLICATION SENSITIVITY REQUIREMENTS; THE SYSTEM USES A LOW SAMPLE VOLUME OF ONLY 125 L PER PLATE WELL. 10.5 X 17.9 X 12.9 IN.
III PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) ANALYZER, CONTAMINENT DETECTION BIOLOGICAL SAMPLE
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) ANALYZER, CONTAMINENT DETECTION BIOLOGICAL SAMPLE
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) ANALYZER, CONTAMINANT DETECTION BIOLOGICAL SAMPLE
SPECIAL FEATURES
(FEAT) USES MSD'S MULTI-ARRAY ELECTROCHEMILUMINESCENCE (ECL) TECHNOLOGY TO CARRY OUT HIGHLY SENSITIVE, MULTIPLEXED IMMUNOASSAYS FOR BIOTHREAT AGENTS; THE PR2 WORKS WITH 96-WELL ASSAY PLATES; EACH WELL OF THE PLATE HAS AN ARRAY OF UP TO 25 DIFFERENT ANTIBODIES TO ENABLE MULTIPLE TARGETS, LIKE BACTERIA, VIRUSES AND TOXINS, TO BE MEASURED SIMULTANEOUSLY; THE PR2 CAN BE USED TO TEST A WIDE VARIETY OF SAMPLE TYPES INCLUDING MANY CLINICAL MATRICES, DRY FILTER UNIT EXTRACTS AEROSOL, FOOD, BEVERAGE, WATER, AND SOIL SAMPLES; MSD HAS OVER 30 ASSAYS FOR BIOTHREAT AGENTS INCLUDING TOXIN, BACTERIAL, AND VIRAL TARGETS; NEW ASSAYS CAN BE ADDED TO EXISTING KITS/PANELS TO ADDRESS NEW THREATS OR ENTIRELY NEW PANELS CAN BE DEVELOPED TO MEET NEW DEMANDS; TIME TO RESULTS VARY FROM 15 MINUTES TO 60 MINUTES DEPENDING ON APPLICATION SENSITIVITY REQUIREMENTS; THE SYSTEM USES A LOW SAMPLE VOLUME OF ONLY 125 L PER PLATE WELL. 10.5 X 17.9 X 12.9 IN: CONTAINS:SECTOR PR2 MODEL 1800,RUGGEDIZED LAPTOP,
SUPPLEMENTARY FEATURES
(SUPP) AND HARD SIDE CASE.

Manufacturer Part Numbers


Related Inventory

60YZ99
11515012SF
Condition NE
Rotary Shaft Se
Readily Available
53WT97
11515012SCV
Condition NE
Rotary Shaft Se
Readily Available
457Y42
11515012SC
Condition NE
Rotary Shaft Se
Readily Available
61AG13
11515012TF
Condition NE
Rotary Shaft Se
Readily Available
53WT98
11515012TCV
Condition NE
Rotary Shaft Se
Readily Available
52VZ94
11515012TC
Condition NE
Rotary Shaft Se
Readily Available
0461-5-15-01-21-27-0
Condition NE
Readily Available
151-5012
Condition NS
CONNECTOR*
Readily Available


 
Top