NSN 6635-00-994-2157, 6635009942157
X-RAY APPARATUS,RADIOGRAPHIC,IND

Federal Supply Classification
FSC 6635 - Physical Properties Testing and Inspection
National Item Identification Number
NIIN 009942157
Codification Country
United States
Item Name Code
INC 13192
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6635-00-994-2157
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6635-00-994-2157


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6635-00-994-2157

National Stock Number (NSN) 6635-00-994-2157, or NIIN 009942157, (x-ray apparatus,radiographic,ind) was assigned January 1, 1960 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 13192. [A PORTABLE, MOBILE, OR STATIONARY DEVICE USUALLY CONSISTING OF AN X-RAY TUBE, TRANSFORMER, CONTROL, AND ASSOCIATED DEVICES DESIGNED FOR RADIOGRAPHIC INSPECTION OF MATERIALS.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6635009942157 does not contain precious metals.

This NSN is associated to Schedule B 9022190000: apparatus based on the use of x-rays for other use, except medical, surgical, dental or veterinary, including radiography or radiotherapy apparatus. The Schedule B End Use is listed as laboratory testing instruments. NAICS classification category 334517: irradiation apparatus manufacturing.

This information was last updated on .


Technical Characteristics

ERR DEFAULT
(CYJY) ERR DEFAULT
ACCESSORY COMPONENTS AND QUANTITY
(AKYD) OPERATION AND MAINTENANCE MANUAL 1; TUBE HEAD RUGGEDIZED TRANSIT CASE 1; CONTROLLER RUGGEDIZED TRANSIT CASE 1; COOLER RUGGEDIZED TRANSITCASE 1; CABLING AND HOSE RUGGEDIZED TRANSIT CASE 1; 2 EXTRA KEYS FOR CONTROL UNIT SAFETY LOCK 1; POWER CABLE ASSY 100 FT WITH STRAIN RELIEF 1; CONTROL CABLE ASSY 100 FT WITH STRAIN RELIEF 1; COOLER POWER CABLE 50 FT WITH STRAIN RELIEF 1; COOLANT HOSE-TWIN, 50 FT, SELF-SEALING G CONNECTOR 1; LIGHTWEIGHT LASER POINTER, REMOVABLE, TO PROVIDE PRECISE TARGETING OF X-RAY BEAM UP TO 50FT
CONTROL TYPE
(AQZF) MOBILE
CURRENT RATING IN AMPS
(AMPS) 10.0
CURRENT TYPE
(ACDC) AC
DESIGN TYPE
(APGF) PORTABLE
FREQUENCY IN HERTZ
(FREQ) 60.0
OPERATION METHOD
(APHE) MANUAL
SPECIAL FEATURES
(FEAT) 160KVCP; X-RAY TUBE HEAD-DIRECTIONAL,CONSTANT POTENTIAL,END-GROUNDED,GAS INSULATED; CONTROL UNIT-DIGITAL MICROCOMPUTER BASED; TUBE WINDOW 0.093 IN. THICH; BEAMANGLE FROM SIDE W/APPROX 40 DEG CONE OF RADIATION
PHASE
(FAAZ) SINGLE
RADIOGRAPHIC TIMER TYPE
(CLPX) EXPOSURE
TUBE COOLING METHOD
(CLPG) WATER
TUBE MOUNTING TYPE
(CLPH) TUBE STAND
TUBE QUANTITY
(ARNF) 1
TUBE STAND MOUNTING TYPE
(CLPR) BASE
TUBE TYPE
(AWGH) SINGLE FOCUS
VOLTAGE IN VOLTS
(ELEC) 100.0 AND 250.0
X-RAY DOSAGE IN NANOSECONDS
(CYJY) 4

Manufacturer Part Numbers


Related Inventory



 