ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6635-01-722-1308, 6635017221308
TRANSDUCER,ULTRASONIC TEST

Federal Supply Classification
FSC 6635 - Physical Properties Testing and Inspection
National Item Identification Number
NIIN 017221308
Codification Country
United States
Item Name Code
INC 45466
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6635-01-722-1308
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6635-01-722-1308


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6635-01-722-1308

National Stock Number (NSN) 6635-01-722-1308, or NIIN 017221308, (transducer,ultrasonic test) was assigned July 15, 2024 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 45466. [AN ITEM DESIGNED TO CONVERT ELECTRICAL SIGNALS INTO MECHANICAL VIBRATIONS OR ULTRASOUND BEAMS. THESE SIGNALS ARE PASSED THROUGH A MATERIAL AND ARE REFLECTED AND SCATTERED BY ANY DISCONTINUITIES (FLAWS) BACK TO THE RECEIVING UNIT WHERE THEY ARE RECONVERTED TO ELECTRICAL SIGNALS AND AMPLIFIED FOR PROCESSING ON AN INDICATOR FOR INTERPRETATION. SEE ALSO TRANSDUCER, SUPERSONIC TEST.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6635017221308 contains an unknown precious metal.

This NSN is associated to Schedule B 9027509000: instrument and apparatus for physical or chemical analysis using optical radiations, nesoi. The Schedule B End Use is listed as laboratory testing instruments. NAICS classification category 334516: analytical laboratory instrument manufacturing.

This information was last updated on .


Technical Characteristics

CASE MATERIAL
(CWJK) STEEL CORROSION RESISTING AND PLASTIC
END ITEM IDENTIFICATION
(AGAV) TRANSDUCER, FLOW
OVERALL LENGTH
(ABHP) 40.0 MILLIMETERS NOMINAL
OVERALL WIDTH
(ABMK) 22.0 MILLIMETERS NOMINAL
MATERIAL
(MATT) STEEL CORROSION RESISTING AND PLASTIC CASE
OPERATING TEMP RANGE
(AFGA) -40.0 TO 130.0 CELSIUS
OVERALL HEIGHT
(ABKW) 25.5 MILLIMETERS NOMINAL
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) SHEAR WAVE TRANSDUCER
SPECIAL FEATURES
(FEAT) FREQUENCY: 4 MHZ
OPERATING TEMP RANGE
(AFGA) -40.0 TO 130.0 DEG CELSIUS

Manufacturer Part Numbers


Related Inventory



 