MICROSCOPE,OPTICAL

Federal Supply Classification
FSC 6650 - Optical Instruments, Test Equipment, Components and Accessories
National Item Identification Number
NIIN 010685021
Codification Country
United States
Item Name Code
INC 09176
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6650-01-068-5021
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6650-01-068-5021


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6650-01-068-5021

National Stock Number (NSN) 6650-01-068-5021, or NIIN 010685021, (microscope,optical) was assigned November 25, 1978 in the Federal Logistics Information System (FLIS). This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 02, 1991, this NSN's acquisition method was noted as: Not established. Not established.

This NSN is assigned to Item Name Code (INC) 09176. [AN OPTICAL INSTRUMENT USED AS AN ASSISTANCE TO THE EYE OR CAMERA IN VIEWING OR PHOTOGRAPHING MINUTE CLOSE OBJECTS. THE ESSENTIAL PARTS OF A MICROSCOPE COMPRISE AN OPTICAL SYSTEM CONSISTING OF SEPARATE OBJECTIVE AND OCULAR LENS ASSEMBLIES WHICH PROVIDE GREATER MAGNIFICATIONS THAN CAN BE OBTAINED WITH A SINGLE LENS ASSEMBLY. EXCLUDES:MAGNIFIER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6650010685021 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

OBJECTIVE TYPE
(BMTH) DRY AND DRY AND DRY AND OIL IMMERSION
SUBSTAGE CONDENSER DESIGN
(BPFC) ABBE
POLARIZER
(BPFG) NOT PROVIDED
EYEPIECE MAGNIFICATION
(BPFY) 10
UNABLE TO DECODE
(ABRY) UNABLE TO DECODE
ACCESSORY COMPONENTS AND QUANTITY
(AKYD) BASE ILLUMINATOR W/TRANSFORMER 1
DESIGN TYPE
(APGF) RESEARCH MODEL
FOCUSING TYPE
(BCTD) ADJUSTABLE
UNABLE TO DECODE
(BLPR) UNABLE TO DECODE AND UNABLE TO DECODE AND UNABLE TO DECODE AND UNABLE TO DECODE
STAGE TYPE
(BMMH) MECHANICAL
OBJECTIVE TYPE
(BMTH) DRY AND OIL IMMERSION
BODY TUBE BERTRAND LENS
(BMMC) NOT PROVIDED
UNABLE TO DECODE
(BMMH) UNABLE TO DECODE
NUMERIC APERTURE
(BMTB) 1.25
UNABLE TO DECODE
(BPFF) UNABLE TO DECODE
OBJECTIVE QUANTITY
(BPFM) 1 AND 1 AND 1 AND 1
UNABLE TO DECODE
(BPFY) UNABLE TO DECODE
BODY TUBE INTERCHANGEABILITY FEATURE
(BMLZ) PROVIDED
IRIS DIAPHRAGM TYPE
(BPFF) CENTERABLE
UNABLE TO DECODE
(BPFX) UNABLE TO DECODE
UNABLE TO DECODE
(AFJU) UNABLE TO DECODE
UNABLE TO DECODE
(AKYD) UNABLE TO DECODE
UNABLE TO DECODE
(BCTD) UNABLE TO DECODE
UNABLE TO DECODE
(BLGP) UNABLE TO DECODEUNABLE TO DECODE AND UNABLE TO DECODE AND UNABLE TO DECODE
UNABLE TO DECODE
(BMLZ) UNABLE TO DECODE
UNABLE TO DECODE
(BMSX) UNABLE TO DECODEUNABLE TO DECODE AND UNABLE TO DECODE AND UNABLE TO DECODE
UNABLE TO DECODE
(BPFC) UNABLE TO DECODE
UNABLE TO DECODE
(ALBY) UNABLE TO DECODE
UNABLE TO DECODE
(BMLW) UNABLE TO DECODE
BODY TUBE ANALYZER
(BMMB) NOT INCLUDED
UNABLE TO DECODE
(BMTB) UNABLE TO DECODE
UNABLE TO DECODE
(BPFK) UNABLE TO DECODE
UNABLE TO DECODE
(BPFM) UNABLE TO DECODEUNABLE TO DECODE AND UNABLE TO DECODE AND UNABLE TO DECODE
FUNNEL STOP DESIGN FEATURE
(BPFP) NOT PROVIDED AND NOT PROVIDED AND NOT PROVIDED AND NOT PROVIDED
OBJECTIVE IRIS DIAPHRAGM
(BPFQ) PROVIDED
STAGE SHAPE
(BMMF) RECTANGULAR
STAGE MATERIAL
(BMMG) ALUMINUM
COVER GLASS CORRECTION COLLAR
(BMSZ) NOT PROVIDED AND NOT PROVIDED AND NOT PROVIDED AND NOT PROVIDED
UNABLE TO DECODE
(BPFG) UNABLE TO DECODE
NOSEPIECE PLACE QUANTITY
(BPFL) 4
UNABLE TO DECODE
(BPFP) UNABLE TO DECODEUNABLE TO DECODE AND UNABLE TO DECODE AND UNABLE TO DECODE
UNABLE TO DECODE
(BPFW) UNABLE TO DECODE
UNABLE TO DECODE
(ABGL) UNABLE TO DECODE
LENGTH
(ABRY) 175.0 MILLIMETERS NOMINAL
NONSTEREOSCOPIC TYPE
(BMLT) TRINOCULAR
MOUNTED CROSS HAIRS
(BMSR) NOT PROVIDED
COVER GLASS CORRECTION COLLAR
(BMSZ) NOT PROVIDED
NOSEPIECE DESIGN
(BPFK) TURRET
OBJECTIVE QUANTITY
(BPFM) 4
UNABLE TO DECODE
(BPFR) UNABLE TO DECODE
WIDTH
(ABGL) 137.0 MILLIMETERS NOMINAL
LENS TYPE
(BLGP) PLANOCHROMATIC
UNABLE TO DECODE
(BMMB) UNABLE TO DECODE
UNABLE TO DECODE
(BMSZ) UNABLE TO DECODEUNABLE TO DECODE AND UNABLE TO DECODE AND UNABLE TO DECODE
UNABLE TO DECODE
(BMTH) UNABLE TO DECODE AND UNABLE TO DECODEUNABLE TO DECODE AND UNABLE TO DECODE
CONDENSER ADJUSTABILITY
(BPFD) ADJUSTABLE
UNABLE TO DECODE
(BPFL) UNABLE TO DECODE
MOUNTED MICROMETER SCALE
(BPFR) NOT PROVIDED
CARRYING CASE
(AFJU) NOT PROVIDED
MAGNIFICATION
(BLPR) 2.5X NOMINAL AND 10.0X NOMINAL AND 40.0X NOMINAL AND 100.0X NOMINAL
USAGE DESIGN
(ALBY) BIOLOGY
LENS TYPE
(BLGP) PLANACHROMATIC AND PLANACHROMATIC AND PLANACHROMATIC AND PLANACHROMATIC
BODY TUBE ACCESSROY SLOT
(BMMD) NOT PROVIDED
LENS COATING FEATURE
(BMSX) COATED AND COATED AND COATED AND COATED
EYEPIECE DESIGNATOR
(BPFX) WIDE FIELD
BODY TUBE POSITION
(BMLW) VERTICAL
UNABLE TO DECODE
(BMMD) UNABLE TO DECODE
UNABLE TO DECODE
(BMMG) UNABLE TO DECODE
DISC INSERT USAGE DESIGN
(BMST) NOT PROVIDED
UNABLE TO DECODE
(BMST) UNABLE TO DECODE
UNABLE TO DECODE
(BPFD) UNABLE TO DECODE
OBJECTIVE IRIS DIAPHRAGM
(BPFQ) PROVIDED AND PROVIDED AND PROVIDED AND PROVIDED
III USAGE DESIGN
(ALBY) BIOLOGY
UNABLE TO DECODE
(APGF) UNABLE TO DECODE
UNABLE TO DECODE
(BMLT) UNABLE TO DECODE
UNABLE TO DECODE
(BMMC) UNABLE TO DECODE
UNABLE TO DECODE
(BMMF) UNABLE TO DECODE
UNABLE TO DECODE
(BMSR) UNABLE TO DECODE
LENS COATING FEATURE
(BMSX) COATED
FUNNEL STOP DESIGN FEATURE
(BPFP) NOT PROVIDED
UNABLE TO DECODE
(BPFQ) UNABLE TO DECODEUNABLE TO DECODE AND UNABLE TO DECODE AND UNABLE TO DECODE
EYEPIECE QUANTITY
(BPFW) 2