National Stock Number
6650-01-218-4742
National Stock Number (NSN) 6650-01-218-4742, or NIIN 012184742, (prism,optical instrument) was assigned October 12, 1985 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.
There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, there are no suppliers listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.
This part number has not been procured by the US Government in over 5 years.
There has been very little demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jan 05, 2005, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
This NSN is assigned to Item Name Code (INC) 21879. [A TRANSPARENT ITEM WITH AT LEAST TWO POLISHED PLANE SURFACES INCLINED TOWARD EACH OTHER, DESIGNED FOR USE IN OPTICAL INSTRUMENTS TO REFLECT AND/OR REFRACT A BEAM OF LIGHT. IT MAY HAVE ONE OR MORE MIRRORED SURFACES FOR GREATER REFLECTION. INCLUDES OPTICAL WEDGES USED TO DIVERT PATHS OF LIGHT BY REFRACTION, BUT TO A LESSER DEGREE. SEE ALSO BEAM SPLITTER, OPTICAL INSTRUMENT.]. This item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input). There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6650012184742 contains an unknown precious metal.
This NSN is associated to Schedule B 9018500000: other ophthalmic instruments and appliances and parts and accessories. The Schedule B End Use is listed as medicinal equipment. NAICS classification category 339112: surgical and medical instrument manufacturing.
This information was last updated on Aug 01, 2025.