ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6665-01-342-7747, 6665013427747
RADIAC SET

Federal Supply Classification
FSC 6665 - Hazard-Detecting Instruments and Apparatus
National Item Identification Number
NIIN 013427747
Codification Country
United States
Item Name Code
INC 07331
Criticality
(S) The item is a non-aviation Critical Safety Item (CSI) whose failure will result in serious damage to equipment or serious injury or death to personnel.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6665-01-342-7747
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6665-01-342-7747


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6665-01-342-7747

National Stock Number (NSN) 6665-01-342-7747, or NIIN 013427747, (radiac set) was assigned July 29, 1991 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Nov 02, 2015, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 07331. [A FIXED NUMBER OF COMPONENTS AND/OR ITEMS, NOT ALL HAVING THE SAME BASIC NAME, WHICH ARE USED TO DETECT, MEASURE AND/OR COMPUTE RADIOACTIVITY. THEY MAY OR MAY NOT INDICATE SIMULTANEOUSLY.]. The item is a non-aviation Critical Safety Item (CSI) whose failure will result in serious damage to equipment or serious injury or death to personnel. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 6665013427747 does not contain precious metals.

This NSN is associated to Schedule B 9022298000: apparatus based on the use of alpha, beta or gamma radiations for other use, nesoi. The Schedule B End Use is listed as laboratory testing instruments. NAICS classification category 334517: irradiation apparatus manufacturing.

This information was last updated on .


Technical Characteristics

RADIATION RANGE PER HOUR
(APPJ) +0.0/+5.0 ROENTGENS
CURRENT TYPE
(ACDC) DC
DOSE RATE PER HOUR
(CTJX) +0.0 TO 1000.0 RAD
ACCESSORY COMPONENT QUANTITY
(AFHS) 1 1ST ACCESSORY
ACCESSORY COMPONENT QUANTITY
(AFHS) 1 3RD ACCESSORY
ACCESSORY COMPONENT QUANTITY
(AFHS) 1 4TH ACCESSORY
ACCESSORY COMPONENT QUANTITY
(AFHS) 1 5TH ACCESSORY
ACCESSORY COMPONENT QUANTITY
(AFHS) 1 2ND ACCESSORY
ACCESSORY CONTROLLING AGENCY
(AKVY) NUCLEAR RESEARCH CORP.
ACCURACY IN PERCENT
(APPN) -10.0 TO 10.0 AT FULL SCALE
DETECTING ELEMENT TYPE
(AMRX) GEIGER TUBE AND SCINTILLATION
FURNISHED ITEMS
(AFJH) SURVEY METER P/N 702454; GUN HANDLE P/N 703231; CARRYING CASE P/N 702464; POUCH P/N 702465 AND STRAP P/N 703272
INDICATOR TYPE
(AMKD) DIRECT READING
INTERNAL BATTERY ACCOMMODATION
(ALSF) INCLUDED
RADIATION RANGE PER HOUR
(APPJ) +0.0 TO 5.0 ROENTGENS
RADIATION TYPE AND FUNCTION
(AMRM) ALPHA RAYS MEASURES
RADIATION TYPE AND FUNCTION
(AMRM) BETA RAYS MEASURES
RADIATION TYPE AND FUNCTION
(AMRM) GAMMA RAYS MEASURES
RADIATION TYPE AND FUNCTION
(AMRM) NEUTRON RAYS MEASURES
RADIATION TYPE AND FUNCTION
(AMRM) X-RAYS MEASURES
SPECIAL FEATURES
(FEAT) PORTABLE ITEM; CAN BE REPLACED BY ADM300 KIT A NSN 6665-01-363-6213 OR ADM300 KIT C NSN 6665-01-320-4712; NON-AVIATION CRITICAL SAFETY ITEM
VOLTAGE IN VOLTS AND CURRENT TYPE
(CSBH) 9.0 DC
DOSE RATE PER HOUR
(CTJX) +0.0/+1000.0 RAD
ACCESSORY COMPONENT QUANTITY
(AFHS) 1
ACCURACY IN PERCENT
(APPN) -10.0/+10.0 AT FULL SCALE
ERR DEFAULT
(CTJX) ERR DEFAULT
VOLTAGE IN VOLTS
(ELEC) 9.0

Manufacturer Part Numbers


Related Inventory



 