NSN 6665-01-426-5071, 6665014265071
VERIFICATION KIT,RADIAC

Federal Supply Classification
FSC 6665 - Hazard-Detecting Instruments and Apparatus
National Item Identification Number
NIIN 014265071
Codification Country
United States
Item Name Code
INC 77777
Criticality
(S) The item is a non-aviation Critical Safety Item (CSI) whose failure will result in serious damage to equipment or serious injury or death to personnel.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6665-01-426-5071
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6665-01-426-5071


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6665-01-426-5071

National Stock Number (NSN) 6665-01-426-5071, or NIIN 014265071, (verification kit,radiac) was assigned March 13, 1996 in the Federal Logistics Information System (FLIS). This NSN does not replace any other NSNs.

There are 3 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Aug 18, 2002, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 77777. The item is a non-aviation Critical Safety Item (CSI) whose failure will result in serious damage to equipment or serious injury or death to personnel. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 6665014265071 does not contain precious metals.

This information was last updated on .


Technical Characteristics

FUNCTIONAL DESCRIPTION
(FTLD) CONSISTS OF THE TS-100 TEST SOURCES AND GCF-200 (V2) TEST FIXTURE, IS USED TO VERIFY THE OPERATION OF THE ADM300A RADIOLOGICAL ASSESSMENT KITS; THEKITS CONSIST OF AN ADM300A SURVEY METER AND PROBES; IF THE DISPLAYED READINGIS WITHIN THE LISTED EXPECTED READING THE ADM300 OR PROBE IS WORKING AND READY FOR USE
SPECIAL FEATURES
(FEAT) 2 RADIOACTIVE SOURCES ARE INCLUDED, 8 UCI CS-137 CESIUM AND 30 NCI TH-232 THORIUM; THE TEST FIXTURE IS USED TO PROVIDE A REFERENCE GEOMETERY FOR THE CESIUM SOURCE; THE THORIUM SOURCE IS ATTACHED TO A PLASTIC HOUSING THAT ACTS AS A REFERENCE GEOMETERY; REFERENCE GEOMETERIES ARE SHOWN ON THE THORIUM SOURCE AND THE TEST SOURCE KIT INSIDE LID; NON-AVIATION CRITICAL SAFETY ITEM. TECHNICAL DATA REF TO 11H2-2-31
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) TEST VERIFICATION KIT
RADIOACTIVE CONTENT
(RADC) CONTAINS RADIOACTIVE MATERIAL
RADIONUCLIDES DATA
(RADD) 8.000 MICROCURIES CESIUM (55) CS-137

Manufacturer Part Numbers


Related Inventory



 
Top