ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6685-00-239-4010, 6685002394010
Cancelled -> Replaced by 6660005268257

Federal Supply Classification
FSC 6685 - Pressure, Temperature, and Humidity Measuring and Controlling Instruments
National Item Identification Number
NIIN 002394010
Codification Country
United States
Item Name Code
INC 42787
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6685-00-239-4010
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6685-00-239-4010


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6685-00-239-4010

National Stock Number (NSN) 6685-00-239-4010, or NIIN 002394010, (thermometer,self-indicating) was assigned January 1, 1963 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 6660005268257.

There are no manufacturer part numbers associated to this NSN.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 42787. [AN ITEM THAT HAS CONFINED LIQUID WHOSE PHYSICAL PROPERTY(IES) CHANGES WITH VARIATION IN TEMPERATURE AND INDICATES THE TEMPERATURE TO A DIVISION OR NUMBER ON A GRADUATED SCALE(S). MAY INCLUDE FLEXIBLE TUBING (CAPILLARY) FOR INDOOR/OUTDOOR APPLICATIONS. EXCLUDES: THERMOMETER, CLINICAL, HUMAN.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 6685002394010 does not contain precious metals.

This NSN is associated to Schedule B 9025114000: thermometers liquid-filled, for direct reading, except clinical. The Schedule B End Use is listed as cell phones and other household goods, n.e.c.. NAICS classification category 334519: other measuring and controlling device manufacturing.

This information was last updated on .


Technical Characteristics

ACTUATING MEDIUM
(BKCM) MERCURY
DESIGN TYPE
(APGF) FLUCTUATING
FEATURES PROVIDED
(CBBL) EXPANSION CHAMBER
OVERALL LENGTH
(ABHP) 12.000 INCHES NOMINAL
NONDEFINITIVE SPEC/STD DATA
(ZZZT) NO. ML-7 TYPE
SCALE ACCURACY RATING
(BKCN) 0.4 TO 0.8 PERCENT OF RANGE
SCALE INSCRIPTION/BACKGROUND COLOR
(BGKZ) BLACK MARKING ON WHITE BACKGROUND
SCALE SMALLEST INCREMENT
(AWAG) 1.0 DEG FAHRENHEIT
SCALE TYPE
(ATEQ) ETCHED STEM
SPECIAL FEATURES
(FEAT) UPPER END OF STEM ETCHED GENERAL
III SCALE SMALLEST INCREMENT
(AWAG) 1.0 DEG FAHRENHEIT
III SCALE INSCRIPTION/BACKGROUND COLOR
(BGKZ) BLACK MARKING ON WHITE BACKGROUND
III SCALE ACCURACY RATING
(BKCN) 0.4 TO 0.8 PERCENT OF RANGE

Manufacturer Part Numbers


Related Inventory



 
Top