ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6695-00-844-6987, 6695008446987
Cancelled -> Replaced by 2540008482671

Federal Supply Classification
FSC 6695 - Combination and Miscellaneous Instruments
National Item Identification Number
NIIN 008446987
Codification Country
United States
Item Name Code
INC 19067
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6695-00-844-6987
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6695-00-844-6987


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6695-00-844-6987

National Stock Number (NSN) 6695-00-844-6987, or NIIN 008446987, (bezel,instrument mounting) was assigned December 30, 1966 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 2540008482671.

There are 2 manufacturer part numbers associated with this NSN. 2 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, there are no suppliers listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 19067. [AN ITEM, USUALLY IN THE FORM OF A FLANGED RIM, DESIGNED TO FIT OVER THE FRONT OF A DIAL INSTRUMENT TO SECURE IT IN PLACE IN AN INSTRUMENT PANEL, OR THE LIKE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6695008446987 contains an unknown precious metal.

This NSN is associated to Schedule B 9026900000: parts and accessories for instruments and apparatus for measuring or checking the flow, level, pressure or other variables of liquids or gases. The Schedule B End Use is listed as measuring, testing, control instruments. NAICS classification category 334513: instruments and related products manufacturing for measuring, displaying, and controlling industrial process variables.

This information was last updated on .


Technical Characteristics

SURFACE TREATMENT
(SURF) CHROME PLATED
UNABLE TO DECODE
(MATL) UNABLE TO DECODE
MATERIAL
(MATL) ZINC ALLOY
UNABLE TO DECODE
(SURF) UNABLE TO DECODE
CONSTRUCTION TYPE
(ADTS) ONE-PIECE
CUTOUT LOCATION
(BFBQ) RIGHT AND LEFT HAND CORNERS;UPPER LEFT CORNERS
DIAL APERTURE KNOB CUTOUT FEATURE
(BFBM) INCLUDED
DIAL APERTURE KNOB CUTOUT QUANTITY
(BFBN) 3
DIAL APERTURE SHAPE
(BFBK) ROUND
DIAL APERTURE SIZE
(BFBL) 0.8750 IN. DIA
INSTRUMENT SIZE FOR WHICH DESIGNED
(BBYZ) 1.094 IN. DIA BY 0.906 IN. LONG
KNOB CUTOUT SIZE
(BFBP) 0.625 IN. RADIUS BY 0.906 IN. DEEP
OVERALL DIAMETER
(ADAV) 1.500 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 0.906 INCHES NOMINAL
MATERIAL
(MATT) ZINC ALLOY
MOUNTING HOLE CONFIGURATION
(AZSY) ROUND
MOUNTING HOLE QUANTITY
(ABTJ) 1
MOUNTING HOLE SIZE
(AZFN) 1.000 IN. DIA
MOUNTING METHOD
(AXGY) TURNLOCK FASTENER
SPECIAL FEATURES
(FEAT) ACC-OFF-ON AND START MARKED ON FACE
SURFACE TREATMENT
(SFTT) CHROMIUM

Manufacturer Part Numbers


Related Inventory



 
Top