ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5950-00-827-8673, 5950008278673
Cancelled -> Replaced by 5950007891311

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 008278673
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-00-827-8673
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-00-827-8673


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-00-827-8673

National Stock Number (NSN) 5950-00-827-8673, or NIIN 008278673, (transformer,power) was assigned January 1, 1962 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 5950007891311.

There are 4 manufacturer part numbers associated with this NSN. 2 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 5 suppliers. Today, 3 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is somewhat common among different platforms, belonging to 4 different weapons systems.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jun 02, 2006, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950008278673 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

FREQUENCY RATING
(ACZB) 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
BODY HEIGHT
(ADAU) 3.125 INCHES NOMINAL
BODY LENGTH
(ADAQ) 3.375 INCHES NOMINAL
BODY WIDTH
(ADAT) 2.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING
(ACZB) 50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPE
(AKNA) OPEN
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY
(AKPV) 4 SINGLE GROUP
MOUNTING METHOD
(AXGY) FLANGE AND SLOT SINGLE GROUP
MOUNTING SLOT WIDTH
(ABTD) 0.344 INCHES NOMINAL SINGLE GROUP
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
WINDING FUNCTION AND QUANTITY
(BPLC) 2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT
(CRBZ) 2.0 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 47.00 AC VOLTS NOMINAL AND 71.00 AC VOLTS NOMINAL AND 97.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY
WINDING OPERATING VOLTAGE
(CWJS) 5.85 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 97.00 AC VOLTS NOMINAL AND 100.00 AC VOLTS NOMINAL AND 117.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY
TERMINAL TYPE AND QUANTITY
(TTQY) 12 TAB, SOLDER LUG
WINDING FUNCTION AND QUANTITY
(BPLC) 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
MOUNTING METHOD
(AXGY) FLANGE SINGLE GROUP AND SLOT SINGLE GROUP

Manufacturer Part Numbers

260417320

RNCC
5
RNVC
9
778205

RNCC
5
RNVC
2
RT201

RNCC
5
RNVC
9
RT201

RNCC
3
RNVC
9
S26256

RNCC
5
RNVC
2

Related Inventory

11-15144
03M-KIT-PA-28RT-
Condition NE
BOGERT CABLE PI
Readily Available
11-15146
03M-KIT-PA-28RT-
Condition NE
BOGERT CABLE PI
Readily Available
G4320303
3RT20171AK61
Condition NE
IEC Magnetic Co
Readily Available
G4323697
3RT20161AK61
Condition NE
IEC Magnetic Co
Readily Available
G4320206
3RT20151BB42
Condition NE
IEC Magnetic Co
Readily Available
G4320233
3RT20161AB02
Condition NE
IEC Magnetic Co
Readily Available
G4320312
3RT20171AK62
Condition NE
IEC Magnetic Co
Readily Available
G8363818
3RT20162BB42
Condition NE
IECPowerContact
Readily Available
G4320127
3RT20151AB02
Condition NE
IEC Magnetic Co
Readily Available
G4320461
3RT20181AK62
Condition NE
IEC Magnetic Co
Readily Available
G4320294
3RT20171AB02
Condition NE
IEC Magnetic Co
Readily Available
G4320276
3RT20161AP61
Condition NE
IEC Magnetic Co
Readily Available
G4320163
3RT20151AN62
Condition NE
IEC Magnetic Co
Readily Available
G4320337
3RT20161BB42
Condition NE
IEC Magnetic Co
Readily Available
G009981741
3RT2017-1AK61
Condition NE
12A 120VAC S00
Readily Available
G4320531
3RT20181BB443MA0
Condition NE
IEC Magnetic Co
Readily Available
G4320434
3RT20181AB01
Condition NE
IEC Magnetic Co
Readily Available
G1893449
3RT20171FB41
Condition NE
Power Contactor
Readily Available
G8359487
3RT20152KB41
Condition NE
IEC PowerContac
Readily Available
G8360354
3RT20152BB41
Condition NE
IEC PowerContac
Readily Available
G1895454
3RT20151AF01
Condition NE
Power Contactor
Readily Available
G1893476
3RT20152AK61
Condition NE
Power Contactor
Readily Available
G8360677
3RT20172BB42
Condition NE
IEC PowerContac
Readily Available
13Y529
3RT20151AK643MA0
Condition NE
IEC Magnetic Co
Readily Available
13Y530
3RT20151BB443MA0
Condition NE
IEC Magnetic Co
Readily Available
13Y541
3RT20161AK643MA0
Condition NE
IEC Magnetic Co
Readily Available
13Y542
3RT20161BB443MA0
Condition NE
IEC Magnetic Co
Readily Available
13Y553
3RT20171AK643MA0
Condition NE
IEC Magnetic Co
Readily Available
13Y554
3RT20171BB443MA0
Condition NE
IEC Magnetic Co
Readily Available
13Y565
3RT20181AK643MA0
Condition NE
IEC Magnetic Co
Readily Available
13Y566
3RT20181BB443MA0
Condition NE
IEC Magnetic Co
Readily Available
56JZ49
3RT20172FB42
Condition NE
IEC Power Conta
Readily Available
56JZ50
3RT20172KB41
Condition NE
IEC Power Conta
Readily Available
56JZ57
3RT20182BB42
Condition NE
IEC Power Conta
Readily Available
56JZ44
3RT20152AK61
Condition NE
IEC Power Conta
Readily Available
56JZ45
3RT20152AP61
Condition NE
IEC Power Conta
Readily Available
56JZ48
3RT20171FB41
Condition NE
IEC Power Conta
Readily Available
56JW40
3RT20162BB44
Condition NE
IEC Power Conta
Readily Available
56JW41
3RT20162FB42
Condition NE
IEC Power Conta
Readily Available
56JW45
3RT20171AV61
Condition NE
IEC Power Conta
Readily Available
56JW47
3RT20172AB01
Condition NE
IEC Power Conta
Readily Available
56JW48
3RT20172AK62
Condition NE
IEC Power Conta
Readily Available
56JW49
3RT20172BB41
Condition NE
IEC Power Conta
Readily Available
56JW50
3RT20172BB42
Condition NE
IEC Power Conta
Readily Available
56JW51
3RT20181FB41
Condition NE
IEC Power Conta
Readily Available
56JW52
3RT20182FB42
Condition NE
IEC Power Conta
Readily Available
56JW18
3RT20151KB42
Condition NE
IEC Power Conta
Readily Available
56JW19
3RT20152BB41
Condition NE
IEC Power Conta
Readily Available
56JW20
3RT20152BB42
Condition NE
IEC Power Conta
Readily Available
56JW21
3RT20152KB41
Condition NE
IEC Power Conta
Readily Available
56JW22
3RT20152KB42
Condition NE
IEC Power Conta
Readily Available
56JW25
3RT20161AN22
Condition NE
IEC Power Conta
Readily Available
56JW31
3RT20161KB41
Condition NE
IEC Power Conta
Readily Available
56JW36
3RT20162AK61
Condition NE
IEC Power Conta
Readily Available
56JW38
3RT20162AP61
Condition NE
IEC Power Conta
Readily Available
56JW39
3RT20162BB42
Condition NE
IEC Power Conta
Readily Available
13Y558
3RT20181AK62
Condition NE
IEC Magnetic Co
Readily Available
13Y561
3RT20181AP61
Condition NE
IEC Magnetic Co
Readily Available
13Y562
3RT20181AP62
Condition NE
IEC Magnetic Co
Readily Available
13Y563
3RT20181BB41
Condition NE
IEC Magnetic Co
Readily Available
13Y564
3RT20181BB42
Condition NE
IEC Magnetic Co
Readily Available
13Y544
3RT20171AB02
Condition NE
IEC Magnetic Co
Readily Available
13Y545
3RT20171AK61
Condition NE
IEC Magnetic Co
Readily Available
13Y546
3RT20171AK62
Condition NE
IEC Magnetic Co
Readily Available
13Y549
3RT20171AP61
Condition NE
IEC Magnetic Co
Readily Available
13Y550
3RT20171AP62
Condition NE
IEC Magnetic Co
Readily Available
13Y551
3RT20171BB41
Condition NE
IEC Magnetic Co
Readily Available
13Y552
3RT20171BB42
Condition NE
IEC Magnetic Co
Readily Available
13Y555
3RT20181AB01
Condition NE
IEC Magnetic Co
Readily Available
13Y556
3RT20181AB02
Condition NE
IEC Magnetic Co
Readily Available
13Y557
3RT20181AK61
Condition NE
IEC Magnetic Co
Readily Available
13Y528
3RT20151BB42
Condition NE
IEC Magnetic Co
Readily Available
13Y531
3RT20161AB01
Condition NE
IEC Magnetic Co
Readily Available
13Y532
3RT20161AB02
Condition NE
IEC Magnetic Co
Readily Available
13Y533
3RT20161AK61
Condition NE
IEC Magnetic Co
Readily Available
13Y534
3RT20161AK62
Condition NE
IEC Magnetic Co
Readily Available
13Y537
3RT20161AP61
Condition NE
IEC Magnetic Co
Readily Available
13Y538
3RT20161AP62
Condition NE
IEC Magnetic Co
Readily Available
13Y539
3RT20161BB41
Condition NE
IEC Magnetic Co
Readily Available
13Y540
3RT20161BB42
Condition NE
IEC Magnetic Co
Readily Available
13Y543
3RT20171AB01
Condition NE
IEC Magnetic Co
Readily Available
13Y519
3RT20151AB01
Condition NE
IEC Magnetic Co
Readily Available
13Y520
3RT20151AB02
Condition NE
IEC Magnetic Co
Readily Available
13Y521
3RT20151AK61
Condition NE
IEC Magnetic Co
Readily Available
13Y522
3RT20151AK62
Condition NE
IEC Magnetic Co
Readily Available
13Y525
3RT20151AP61
Condition NE
IEC Magnetic Co
Readily Available
13Y526
3RT20151AP62
Condition NE
IEC Magnetic Co
Readily Available
13Y527
3RT20151BB41
Condition NE
IEC Magnetic Co
Readily Available
11-20505
01-CE9865-1110-4
Condition NE
ADS GFC 500 Ins
Readily Available
4777820-503
Condition FN
Desc: BRACKET;
Readily Available


 
Top