NSN 5930-01-300-1817, 5930013001817
SWITCH,THERMOSTATIC

Federal Supply Classification
FSC 5930 - Switches
National Item Identification Number
NIIN 013001817
Codification Country
United States
Item Name Code
INC 00451
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5930-01-300-1817
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5930-01-300-1817


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5930-01-300-1817

National Stock Number (NSN) 5930-01-300-1817, or NIIN 013001817, (switch,thermostatic) was assigned May 11, 1989 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00451. [A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES:CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5930013001817 contains an unknown precious metal.

This NSN is associated to Schedule B 9032100000: thermostats. The Schedule B End Use is listed as measuring, testing, control instruments. NAICS classification category 334512: automatic environmental control manufacturing for residential, commercial, and appliance use.

This information was last updated on .


Technical Characteristics

BODY DIAMETER
(ABPM) 0.618 INCHES MINIMUM AND 0.625 INCHES MAXIMUM
BODY LENGTH
(ADAQ) 3.562 INCHES MINIMUM AND 3.624 INCHES MAXIMUM
CONTACT ACTION STIMULUS
(CQGB) INCREASE
CONTACT ADJUSTABILITY
(CTYC) ACTUATION POINT ADJUSTABLE, PRESET
CONTACT ADJUSTMENT RANGE
(CTYM) -100.00 TO 400.00 ACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE
(CTYS) EXTERNAL ACTUATION POINT SCREW
CONTACT LOAD CURRENT RATING
(CTHF) 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE2.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE
CONTACT STIMULUS RATING
(CTYX) 60.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT
CONTACT VOLTAGE RATING IN VOLTS
(CTZB) 120.0 AC AT SEA LEVEL FIRST VOLTAGE240.0 AC AT SEA LEVEL SECOND VOLTAGE115.0 DC AT SEA LEVEL THIRD VOLTAGE
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION
(ABFE) VIBRATION RESISTANT
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS
(AFDS) 1.082 INCHES NOMINAL
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS
(AFDV) 0.937 INCHES NOMINAL
OVERALL DIAMETER
(ADAV) 1.750 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 4.594 INCHES MINIMUM AND 4.968 INCHES MAXIMUM
MEDIA FOR WHICH DESIGNED
(MEDA) GAS OR LIQUID
MOUNTING FACILITY PATTERN
(CQYJ) ISOSCELES TRIANGLE
MOUNTING METHOD
(AXGY) BRACKET AND THREADED HOLE
NOMINAL THREAD SIZE
(CQJX) 0.164 INCHES ALL THREADED HOLE
NONPILE-UP CONTACT ARRANGEMENT
(CRLD) 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS
(AFDT) 0.540 INCHES NOMINAL
STYLE DESIGNATOR
(STYL) CYLINDRICAL W/FLANGE
TEMP SENSING ELEMENT TYPE
(AKBY) EXPANDING SHELL
TERMINAL TYPE
(CSCF) WIRE LEAD
THREAD CLASS
(AAJD) 2B ALL THREADED HOLE
THREAD SERIES DESIGNATOR
(THSD) UNC ALL THREADED HOLE
THREAD QUANTITY PER INCH
(CMLP) 32 ALL THREADED HOLE
CONTACT ADJUSTMENT RANGE
(CTYM) -100.00/+400.00 ACTUATION POINT DEGREES FAHRENHEIT
III STYLE DESIGNATOR
(STYL) CYLINDRICAL W/FLANGE
III HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION
(ABFE) VIBRATION RESISTANT
III OVERALL LENGTH
(ABHP) 4.594 INCHES MINIMUM AND 4.968 INCHES MAXIMUM