NSN 5925-00-175-5222, 5925001755222
Cancelled -> Replaced by 5925005026716

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 001755222
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(Y) Information is in the Hazardous Materials Information Resource System (HMIRS).
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-00-175-5222
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-00-175-5222


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-00-175-5222

National Stock Number (NSN) 5925-00-175-5222, or NIIN 001755222, (circuit breaker) was assigned January 1, 1963 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 2 stock numbers: 5925005026716, 5925002542675.

There are 6 manufacturer part numbers associated with this NSN. 2 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 3 suppliers. Today, 3 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is unique to one weapons system.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. Information is in the Hazardous Materials Information Resource System (HMIRS). NSN 5925001755222 contains an unknown precious metal.

This NSN is associated to Schedule B 8536200040: automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi. The Schedule B End Use is listed as electric apparatus. NAICS classification category 335313: switchgear and switchboard apparatus manufacturing.

This information was last updated on .


Technical Characteristics

ACTUATOR FUNCTION
(CPRW) TRIP W/SEPARATE RESET
ACTUATOR POSITION DESIGNATION
(CPRX) AT POLE ONE
BODY LENGTH
(ADAQ) 2.187 INCHES NOMINAL
BODY STYLE
(AAQL) SINGLE POLE TYPE
BODY WIDTH
(ADAT) 0.750 INCHES NOMINAL
BUSHING LENGTH
(ABXD) 0.125 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH
(AEBP) 1.125 INCHES NOMINAL
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT SINGLE LOCATION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH
(AEBY) 1.843 INCHES NOMINAL
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED
(CQXF) DUSTPROOF
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 1 PUSH-PULL
MATERIAL
(MATT) PLASTIC CASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 35.0 AMPERES AC AND 35.0 AMPERES DC SINGLE LOCATION
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 2500.0 AC AND 2500.0 DC SINGLE LOCATION
MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 2 THREADED BUSHING
MOUNTING SURFACE TO TERMINAL END DISTANCE
(AJWX) 2.000 INCHES NOMINAL
NOMINAL THREAD SIZE
(CQJX) 0.138 INCHES
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 30.0 AC AND 30.0 DC SINGLE LOCATION
POLE QUANTITY
(AKPX) 1
RESET METHOD
(CPRQ) AUTOMATIC
TERMINAL TYPE AND QUANTITY
(TTQY) 2 SCREW
THREAD SERIES DESIGNATOR
(THSD) UNC
THREAD QUANTITY PER INCH
(CMLP) 32
TRIP RELEASE AMBIENT TEMP RATING
(CRCF) 25.0 CELSIUS MAXIMUM SINGLE LOCATION
TRIP RELEASE CHARACTERISTIC
(CPRL) TIME DELAY SINGLE LOCATION
TRIP RELEASE METHOD
(CPRJ) THERMAL SINGLE LOCATION
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) 55.000 NOMINAL AT 200 PCT SINGLE LOCATION
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 138.0 SINGLE LOCATION
CASE MATERIAL
(ADTV) PLASTIC
TRIP RELEASE AMBIENT TEMP RATING
(CRCF) 25.0 DEG CELSIUS MAXIMUM SINGLE LOCATION
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 30.0 AC SINGLE LOCATION AND 30.0 DC SINGLE LOCATION
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 2500.0 AC SINGLE LOCATION AND 2500.0 DC SINGLE LOCATION
CASE MATERIAL
(CWJK) PLASTIC
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 35.0 AMPERES AC SINGLE LOCATION AND 35.0 AMPERES DC SINGLE LOCATION

Manufacturer Part Numbers

1213P35

RNCC
3
RNVC
2
6127587

RNCC
3
RNVC
2
931135A

RNCC
5
RNVC
9
AN3161P35

RNCC
5
RNVC
2
D6751235

RNCC
5
RNVC
9
MILC7079

RNCC
4
RNVC
1