ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 4130-01-533-0208, 4130015330208
COOLER UNIT,AIR

Federal Supply Classification
FSC 4130 - Refrigeration and Air Conditioning Components
National Item Identification Number
NIIN 015330208
Codification Country
United States
Item Name Code
INC 11361
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 4130-01-533-0208
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 4130-01-533-0208


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 4130-01-533-0208

National Stock Number (NSN) 4130-01-533-0208, or NIIN 015330208, (cooler unit,air) was assigned August 29, 2005 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is unique to one weapons system.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jul 28, 2018, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 11361. [A UNIT COMPRISING A FIN AND TUBE HEAT TRANSFER ELEMENT, FILTERS AND MAY OR MAY NOT HAVE A MOTOR DRIVEN FAN, INCLOSED IN A CASING FOR THE PURPOSE OF COOLING AND REMOVING MOISTURE FROM THE AIR IN A SPACE WHERE THE UNIT IS INSTALLED. IT MAY INCLUDE ELECTRIC HEATER AND/OR ELECTROSTATIC PRECIPITATOR. EXCLUDES:UNITS CONTAINING COMPRESSOR, CONDENSER AND MEANS FOR INTRODUCING AIR FROM OUTSIDE SOURCES.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 4130015330208 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

TUBE MATERIAL
(AWGJ) COPPER
UNABLE TO DECODE
(AWGJ) UNABLE TO DECODE
VOLTAGE IN VOLTS
(ELEC) 440.0 HEATER
PHASE
(FAAZ) THREE FAN MOTOR
FREQUENCY IN HERTZ
(FREQ) 60.0 FAN MOTOR
CURRENT TYPE
(ACDC) AC FAN MOTOR
VOLTAGE IN VOLTS
(ELEC) 440.0 FAN MOTOR
CURRENT TYPE
(ACDC) AC HEATER
PHASE
(FAAZ) THREE HEATER
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
III OVERALL WIDTH
(ABMK) 62.000 INCHES NOMINAL
CASE MATERIAL
(ADTV) STEEL, GALVANIZED
FREQUENCY IN HERTZ
(FREQ) 60.0 HEATER
CASE WITH BUILT-IN CONDENSATE DRAIN PAN
(AWLZ) INCLUDED
COIL TUBE QUANTITY
(AWLQ) 1
CONNECTION TYPE
(AWLS) FLANGE UNION
COOLING MEDIUM
(ACZV) CHILLED WATER
CURRENT TYPE
(ACDC) UNABLE TO DECODE
FAN DRIVE TYPE
(AWMB) DIRECT
FAN TYPE
(AWMA) CENTRIFUGAL
FREQUENCY IN HERTZ
(FREQ) UNABLE TO DECODE
HEATER WATTAGE RATING IN KILOWATTS
(CWMQ) 3.0
MATERIAL
(MATT) COPPER TUBE
MATERIAL
(MATT) STEEL CASE
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) FAN COIL UNIT
PHASE
(FAAZ) UNABLE TO DECODE
NOMINAL CAPACITY IN BTU PER HOUR
(CWMP) 72920.0 HEATING AND 72920.0 COOLING
OPERATING SPEED AT RATED CAPACITY IN RPM
(AEQC) 1800.0
OVERALL DEPTH
(ABFY) 17.000 INCHES NOMINAL
OVERALL HEIGHT
(ABKW) 52.000 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 62.000 INCHES NOMINAL
RETURN CONNECTION SIZE
(AWLW) .625 IN. OD
SPECIAL FEATURES
(FEAT) HIGH IMPACT SHOCK RESISTANT,HAS LVR (LOW VOLTAGE RELEASE) CAPACITY,WITH NON-SEALED INSULATION SYSTEM MOTOR
SUPPLY CONNECTION SIZE
(AWLT) .625 IN. OD
TUBE CIRCUIT QUANTITY
(AWLR) 32
VOLTAGE IN VOLTS
(ELEC) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory



 
Top