ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6515-01-696-5218, 6515016965218
VENTILATOR,VOLUME,PORTABLE

Federal Supply Classification
FSC 6515 - Medical and Surgical Instruments, Equipment, and Supplies
National Item Identification Number
NIIN 016965218
Codification Country
United States
Item Name Code
INC 48820
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6515-01-696-5218
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6515-01-696-5218


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6515-01-696-5218

National Stock Number (NSN) 6515-01-696-5218, or NIIN 016965218, (ventilator,volume,portable) was assigned August 2, 2021 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 5 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 3 suppliers. Today, 3 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 3 suppliers are deemed design controlled or valid supply parts.

This part number has been procured by the US Government within the last year, but shows no recent (last 90 days) procurement activity. There have been 32 contracts issued for this part number, with 31 awards given. There is moderate competition for this NSN. The US Government has awarded contracts to 10 different suppliers. The last contract numbers awarded were: SPE2DS25V7785, SPE2DS24V072S, SPE2DS24V072S, SPE2DS24V072S, SPE2DS24V072S. The total value of the awarded contracts has been US$ 451,749.50.

There has been a small amount of demand for this national stock number. The demand for this NSN originated from less than 5 countries.

This NSN is assigned to Item Name Code (INC) 48820. [AN ITEM DESIGNED TO PROVIDE VENTILATION TO A PATIENT IN TRANSPORT AND/OR DURING INSTITUTIONAL CARE. IT MAY BE IN A TRANSPORT CASE AND PROVIDE TIME CYCLED, PRESSURE LIMITED, PISTON DRIVEN CONSTANT FLOW, BE MICROPROCESSOR CONTROLLED, WITH THREE MODES, CONTROL, ASSIST-CONTROL, SYNCHRONOUS INTERMITTENT MANDATORY VENTILATION PROVIDING SENSITIVITY CONTROL, RECHARGEABLE BATTERY, HOSES, TUBING, CONNECTORS, PATIENT VALVE, AND OTHER RELATED FEATURES.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 6515016965218 does not contain precious metals.

This NSN is associated to Schedule B 9018908000: other instruments and appliances used in medical, surgical, dental or veterinary sciences, nesoi. The Schedule B End Use is listed as medicinal equipment. NAICS classification category 339112: surgical and medical instrument manufacturing.

This information was last updated on .


Technical Characteristics

CURRENT TYPE
(ACDC) AC
FREQUENCY IN HERTZ
(FREQ) 50.0 AND -60.0
PART NAME ASSIGNED BY CONTROLLING AGENCY
(CXCY) VENTILATOR SAVE II+
OVERALL HEIGHT
(ABKW) 13.0 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 16.0 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 7.0 INCHES NOMINAL
PORTABILITY
(APCB) PORTABLE
SPECIAL FEATURES
(FEAT) THE SAVE II+ SERIES ARE INTENDED TO PROVIDE VENTILATORY SUPPORT FOR ADULTS DURING CPR OR WHEN POSITIVE PRESSURE VENTILATION (PPV) IS REQUIRED TO MANAGE ACUTE RESPIRATORY FAILURE (ARF) OR OTHER SITUATIONS WHERE MECHANICAL VENTILATION IS NEEDED. THE SAVE II+ SERIES ARE APPROPRIATE FOR ADULTS THAT WEIGH AT LEAST 45 KG (99 LBS.). IT IS INTENDED TO BE USED IN PREHOSPITAL, FIELD HOSPITALS, OUTPATIENT ENVIRONMENTS, HOSPITALS, ICU S, TRANSPORT ENVIRONMENTS OR ANY OTHER HEALTHCARE ENVIRONMENT REQUIRING THE USE OF A VENTILATOR. EXTENDABLE O2 RESERVOIR P/N:F20072, NOISE ATTENUATOR P/N:M41112, DEBRIS FILTER - AIR INTAKE (2 INSTALLED)P/N:F20053, INTAKE CAP AIR INTAKE (1 INSTALLED) P/N:F20059, AC POWER SUPPLY P/N:M42090, HARD CARRYING CASE P/N:F20065, QUICK SETUP GUIDE, OPERATOR S MANUAL P/N:M42110, HEAT AND MOISTURE EXCHANGER FILTER (1 INSTALLED) P/N:HME OR HMEF, DIMENSIONS VENTILATOR: 6.5" X 6.25" X 2.0" (81 IN3) WEIGHT VENTILATOR: 2.8 LBS. (1.3 KG)
UNIVERSAL MEDICAL DEVICE NOMENCLATURE SYSTEM CODE
(ALUE) 18098
VOLTAGE IN VOLTS
(ELEC) 100.0 AND -240.0

Manufacturer Part Numbers


Related Inventory

S34701-10H-9
S34701-0010H-9
Condition FN
Desc: T-SEAL; M
Readily Available


 
Top