ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5996-01-344-0759, 5996013440759
AMPLIFIER,RADIO FREQUENCY

Federal Supply Classification
FSC 5996 - Amplifiers
National Item Identification Number
NIIN 013440759
Codification Country
United States
Item Name Code
INC 00446
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5996-01-344-0759
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5996-01-344-0759


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5996-01-344-0759

National Stock Number (NSN) 5996-01-344-0759, or NIIN 013440759, (amplifier,radio frequency) was assigned August 22, 1991 in the Federal Logistics Information System (FLIS). NIIN 013440759 was cancelled on January 2, 2020, with a cancelled status of "Item is Cancelled WITHOUT Replacement." There is no known replacement specified for this stock number. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, one supplier is listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

There has been very little demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 01, 2020, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00446. [AN ELECTRONIC DEVICE WHOSE RADIO FREQUENCY INPUT SIGNALS CONTROL POWER FROM A SOURCE INDEPENDENT OF THE INPUT SIGNALS, AND DELIVERS RADIO FREQUENCY OUTPUT SIGNALS OF GREATER AMPLITUDE WITH RESPECT TO CURRENT AND/OR VOLTAGE. THE OUTPUT SIGNALS CHARACTERISTICS ARE UNIFORMLY RELATED TO THE INPUT SIGNALS. IT OPERATES AT FREQUENCIES ABOVE 20 KILOHERTZ.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5996013440759 does not contain precious metals.

This information was last updated on .


Technical Characteristics

CONNECTION CONTACT TYPE AND QUANTITY
(BJBW) 1 COMBAT CONTROL TEAM MEMBERS DRAIN AND 1 WHITWORTH DRAIN AND 2 HYPERBOLOID DRAIN
IDENTIFICATION DESIGNATOR
(AJKH) 10138990-101-4X560
CIRCUIT CONSTRUCTION TYPE
(BHSX) SOLID STATE
OVERALL GAIN
(BHTL) 22.0 DECIBELS
OVERALL HEIGHT
(ABKW) 0.900 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 1.020 INCHES NOMINAL
OPERATING CONTROL METHOD
(ALBM) AUTOMATIC
IMPEDANCE RATING PER CHANNEL
(BHTN) 50.000 OHMS OPERATING CHANNEL
STORAGE TEMP RANGE
(AFJQ) -40.0/+75.0 DEG CELSIUS
INCLOSURE TYPE
(AKNA) ENCASED
CONNECTION TYPE AND LOCATION
(BJBP) CONNECTOR, PLUG LEFT SIDE AND GROUND TERMINAL LEFT SIDE AND RECEPTACLE, COAXIAL LEFT SIDE AND RECEPTACLE, COAXIAL RIGHT SIDE
CONNECTION TYPE AND LOCATION
(BJBP) ERR-060 VERTICAL LINE LADDER AND ERR-060 VERTICAL LINE LADDER AND 35X25 VERTICAL LINE LADDER AND 35X25 ARROWHEAD
ENVIRONMENTAL PROTECTION
(ADZC) MOISTURE PROOF
AVERAGE LIFE MEASUREMENT
(AFSU) NOT RATED
OVERALL LENGTH
(ABHP) 2.391 INCHES NOMINAL
OPERATING TEMP RANGE
(AFGA) +0.0 TO 60.0 DEG CELSIUS
INSTALLATION DESIGN
(AMQY) MECHANICAL
FREQUENCY PER CHANNEL
(BHTB) 3.3214 GIGAHERTZ NOMINAL OPERATING CHANNEL
STORAGE TEMP RANGE
(AFJQ) -40.0 TO 75.0 DEG CELSIUS
CONNECTION TYPE AND LOCATION
(BJBP) ERR-060 THREADED INTERNAL AND ERR-060 THREADED INTERNAL AND DISH, SHERBET THREADED INTERNAL AND DISH, SHERBET YOKE
OPERATING TEMP RANGE
(AFGA) +0.0/+60.0 DEG CELSIUS
BASIC SHAPE STYLE
(AGTA) RECTANGULAR OR SQUARE
CONNECTION CONTACT TYPE AND QUANTITY
(BJBW) 1 CONNECTOR, PLUG EXTERNAL AND 1 GROUND TERMINAL EXTERNAL AND 2 RECEPTACLE, COAXIAL EXTERNAL
CONTROL TYPE
(AQZF) REMOTE
III CIRCUIT CONSTRUCTION TYPE
(BHSX) SOLID STATE
CONNECTION CONTACT TYPE AND QUANTITY
(BJBW) ERR-060 AND ERR-060 AND ERR-060


Related Inventory



 
Top