ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5910-00-081-7625, 5910000817625
Cancelled -> Replaced by 5910008648382

Federal Supply Classification
FSC 5910 - Capacitors
National Item Identification Number
NIIN 000817625
Codification Country
United States
Item Name Code
INC 00007
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5910-00-081-7625
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5910-00-081-7625


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5910-00-081-7625

National Stock Number (NSN) 5910-00-081-7625, or NIIN 000817625, (capacitor,fixed,ceramic dielectr) was assigned December 15, 1967 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 5910008648382.

There are 4 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 4 suppliers. Today, 3 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 2 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

This NSN is fairly common among different weapons systems, belonging to 19 different platforms.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jun 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00007. [A CAPACITOR, WHOSE CAPACITANCE VALUE CANNOT BE ADJUSTED OR VARIED, HAVING A CERAMIC DIELECTRIC. IT MAY BE A SINGLE UNIT, OR CONSIST OF TWO OR MORE FIXED UNITS WHICH CANNOT BE SEPARATED.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5910000817625 contains an unknown precious metal.

This NSN is associated to Schedule B 8532290040: fixed capacitors, nesoi. The Schedule B End Use is listed as electric apparatus.

This information was last updated on .


Technical Characteristics

BODY DIAMETER
(ABPM) 0.300 INCHES NOMINAL
BODY LENGTH
(ADAQ) 0.156 INCHES NOMINAL
BODY STYLE
(AAQL) W/O MTG FACILITIES, RADIAL TERMINALS
CAPACITANCE VALUE PER SECTION
(CQBQ) 1200.000 PICOFARADS SINGLE SECTION
MATERIAL
(MATT) PLASTIC CASE
NONDERATED OPERATING TEMP
(CQJJ) 0.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION
(CQWM) 1000.0 DC SINGLE SECTION
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATOR
(AEBZ) NO COMMON OR GROUNDED ELECTRODE(S)
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS
(CQLZ) 0.0 SINGLE SECTION
TERMINAL LENGTH
(ABJT) 1.500 INCHES MINIMUM
TERMINAL DIAMETER
(AEBT) 0.025 INCHES NOMINAL
TERMINAL SURFACE TREATMENT
(CWSG) SOLDER
TERMINAL TYPE AND QUANTITY
(TTQY) 2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT
(TEST) 09219-VCD0023 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
TOLERANCE RANGE PER SECTION
(CRTP) -20.00 TO 20.00 PERCENT SINGLE SECTION
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS
(CRHD) -60.0 TO 60.0 SINGLE SECTION
III TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS
(CQLZ) 0.0 SINGLE SECTION
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS
(CRHD) -60.0/+60.0 SINGLE SECTION
UNABLE TO DECODE
(ABMK) UNABLE TO DECODE
UNABLE TO DECODE
(ABKW) UNABLE TO DECODE
TOLERANCE RANGE PER SECTION
(CRTP) -20.00/+20.00 PERCENT SINGLE SECTION
CASE MATERIAL
(CWJK) PLASTIC
NONDERATED OPERATING TEMP
(CQJJ) 0.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM

Manufacturer Part Numbers

40C239A

RNCC
E
RNVC
8
40C239A

RNCC
E
RNVC
8
5GAD12

RNCC
3
RNVC
2
C023B102E122M

RNCC
5
RNVC
9
C023B102E122M

RNCC
5
RNVC
2
VCD0023

RNCC
1
RNVC
2
VCD0023

RNCC
C
RNVC
1

Related Inventory



 