ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5910-00-853-4475, 5910008534475
Cancelled -> Replaced by 5910001913808

Federal Supply Classification
FSC 5910 - Capacitors
National Item Identification Number
NIIN 008534475
Codification Country
United States
Item Name Code
INC 00007
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5910-00-853-4475
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5910-00-853-4475


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5910-00-853-4475

National Stock Number (NSN) 5910-00-853-4475, or NIIN 008534475, (capacitor,fixed,ceramic dielectric) was assigned January 1, 1962 in the Federal Logistics Information System (FLIS). NIIN 008534475 was cancelled on July 2, 2013, with a cancelled status of "Item is Cancelled - USE." This NSN was replaced by NSN 5910008056638. This NSN replaces 2 stock numbers: 5910001005755, 5910001913808.

There are no manufacturer part numbers associated to this NSN.

This part number has not been procured by the US Government in over 5 years.

This NSN is assigned to Item Name Code (INC) 00007. [A CAPACITOR, WHOSE CAPACITANCE VALUE CANNOT BE ADJUSTED OR VARIED, HAVING A CERAMIC DIELECTRIC. IT MAY BE A SINGLE UNIT, OR CONSIST OF TWO OR MORE FIXED UNITS WHICH CANNOT BE SEPARATED.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5910008534475 does not contain precious metals.

This information was last updated on .


Technical Characteristics

UNABLE TO DECODE
(ABJT) UNABLE TO DECODE
BODY DIAMETER
(ABPM) 0.225 INCHES NOMINAL
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP
(CQBF) 1000.0 MEGOHMS
UNABLE TO DECODE
(CQLZ) UNABLE TO DECODE
UNABLE TO DECODE
(CRHD) UNABLE TO DECODE
TOLERANCE RANGE PER SECTION
(CRTP) -0.25/+0.25 PICOFARADS SINGLE SECTION
CASE MATERIAL
(CWJK) PLASTIC
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT
(CWPM) 0.1500
NONDERATED OPERATING TEMP
(CQJJ) -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
INSULATION RESISTANCE AT REFERENCE TEMP
(CWPK) 50000.0 MEGOHMS
UNABLE TO DECODE
(ABMK) UNABLE TO DECODE
UNABLE TO DECODE
(AEBZ) UNABLE TO DECODE
CAPACITANCE VALUE PER SECTION
(CQBQ) 1.500 PICOFARADS SINGLE SECTION
UNABLE TO DECODE
(CWPK) UNABLE TO DECODE
TERMINAL SURFACE TREATMENT
(CWSG) SOLDER
UNABLE TO DECODE
(TEST) UNABLE TO DECODE
UNABLE TO DECODE
(CQBQ) UNABLE TO DECODE
UNABLE TO DECODE
(CQJJ) UNABLE TO DECODE AND UNABLE TO DECODE
QUALITY FACTOR AT REFERENCE TEMP
(CWQF) 420.0000
TERMINAL LENGTH
(ABJT) 1.250 INCHES MINIMUM1.250 INCHES MINIMUM1.250 INCHES MINIMUM
UNABLE TO DECODE
(CQWM) UNABLE TO DECODE
TEST DATA DOCUMENT
(TEST) 81349-MIL-C-20 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
BODY STYLE
(AAQL) W/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALSW/O MTG FACILITIES, AXIAL TERMINALS
UNABLE TO DECODE
(ABKW) UNABLE TO DECODE
SCHEMATIC DIAGRAM DESIGNATOR
(AEBZ) NO COMMON OR GROUNDED ELECTRODE(S)
UNABLE TO DECODE
(TTQY) UNABLE TO DECODE
SPECIFICATION/STANDARD DATA
(ZZZK) 81349-MIL-C-20/2 GOVERNMENT SPECIFICATION
UNABLE TO DECODE
(ABPM) UNABLE TO DECODE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION
(CQWM) 500.0 DC SINGLE SECTION
UNABLE TO DECODE
(AAQL) UNABLE TO DECODE
UNABLE TO DECODE
(AEBT) UNABLE TO DECODE
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS
(CRHD) -250.0/+250.0 SINGLE SECTION
UNABLE TO DECODE
(CRTP) UNABLE TO DECODE
UNABLE TO DECODE
(CWJK) UNABLE TO DECODE
UNABLE TO DECODE
(CWQF) UNABLE TO DECODE
UNABLE TO DECODE
(ZZZK) UNABLE TO DECODE
TERMINAL DIAMETER
(AEBT) 0.032 INCHES NOMINAL
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED
BODY LENGTH
(ADAQ) 0.540 INCHES NOMINAL
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS
(CQLZ) -750.0 SINGLE SECTION
UNABLE TO DECODE
(CWPM) UNABLE TO DECODE
UNABLE TO DECODE
(CQBF) UNABLE TO DECODE
TERMINAL TYPE AND QUANTITY
(TTQY) 2 UNINSULATED WIRE LEAD
UNABLE TO DECODE
(AARG) UNABLE TO DECODE
UNABLE TO DECODE
(ADAQ) UNABLE TO DECODE
UNABLE TO DECODE
(CWSG) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory



 