NSN 5925-00-318-2222, 5925003182222
CIRCUIT BREAKER

Federal Supply Classification
FSC 5925 - Circuit Breakers
National Item Identification Number
NIIN 003182222
Codification Country
United States
Item Name Code
INC 00136
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5925-00-318-2222
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5925-00-318-2222


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5925-00-318-2222

National Stock Number (NSN) 5925-00-318-2222, or NIIN 003182222, (circuit breaker) was assigned November 11, 1973 in the Federal Logistics Information System (FLIS). This NSN does not replace any other NSNs.

There is only one manufacturer part number associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 2 suppliers. Today, 2 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. This part is a commercial/non-developmental/off-the-shelf-item. Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00136. [A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5925003182222 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

MOUNTING FACILITY TYPE AND QUANTITY
(AXHR) 6 TERMINAL
CASE MATERIAL
(CWJK) PLASTIC
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 100.0 AMPERES AC AND 100.0 AMPERES DC ALL LOCATIONS
ACTUATOR FUNCTION
(CPRW) TRIP-RESET
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 600.0 AC ALL LOCATIONS AND 250.000 DC ALL LOCATIONS
RESET METHOD
(CPRQ) MANUAL
MANUAL ACTUATOR TYPE AND QUANTITY
(CPRT) 1 TOGGLE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT
(CQWN) 150.000 MINIMUM AT 200 PCT AND 250.000 MAXIMUM AT 200 PCT ALL LOCATIONS
BODY HEIGHT
(ADAU) 3.500 INCHES NOMINAL
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE
(CPLM) 100.0 AMPERES AC ALL LOCATIONS AND 100.0 AMPERES DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 2000.0 AC AND 10000.0 DC ALL LOCATIONS
TRIP RELEASE CHARACTERISTIC
(CPRL) TIME DELAY ALL LOCATIONS
ACTUATOR POSITION DESIGNATION
(CPRX) AT POLE TWO
UNABLE TO DECODE
(ADTV) UNABLE TO DECODE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT
(CPRN) 138.0 ALL LOCATIONS
TERMINAL TYPE AND QUANTITY
(TTQY) 3 CLIP AND 3 COMPRESSION
BODY WIDTH
(ADAT) 4.500 INCHES NOMINAL
TRIP RELEASE METHOD
(CPRJ) THERMAL-MAGNETIC ALL LOCATIONS
CASE MATERIAL
(ADTV) PLASTIC
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS
(CPRF) 600.0 AC AND 250.000 DC ALL LOCATIONS
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS
(CPRG) 2000.0 AC ALL LOCATIONS AND 10000.0 DC ALL LOCATIONS
MAIN CONTACT TRIPPING MECHANISM TYPE
(CPRR) TRIP FREE
BODY LENGTH
(ADAQ) 8.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH
(AEBQ) 1.500 INCHES NOMINAL
FREQUENCY IN HERTZ
(FREQ) 60.0 ALL LOCATIONS
BODY STYLE
(AAQL) MULTIPOLE-SINGLE ACTUATOR TYPE
BOSS HEIGHT
(AJEC) 0.156 INCHES NOMINAL
POLE QUANTITY
(AKPX) 3
CIRCUIT PROTECTION TYPE
(CPRH) OVERCURRENT ALL LOCATIONS
TRIP RELEASE AMBIENT TEMP RATING
(CRCF) 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS