ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 5950-00-538-3661, 5950005383661
Cancelled -> Replaced by 5950006484544

Federal Supply Classification
FSC 5950 - Coils and Transformers
National Item Identification Number
NIIN 005383661
Codification Country
United States
Item Name Code
INC 32496
Criticality
(X) This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5950-00-538-3661
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5950-00-538-3661


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5950-00-538-3661

National Stock Number (NSN) 5950-00-538-3661, or NIIN 005383661, (transformer,power) was assigned January 1, 1961 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN replaces 1 stock number, 5950006484544.

There is only one manufacturer part number associated with this NSN. None of the associated part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by one supplier. Today, there are no suppliers listed as an Active supplier for this NSN. Of the active suppliers, there are no suppliers that are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Jun 02, 2006, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 32496. [A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES:TRANSFORMER (1), PULSE.]. This item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 5950005383661 contains an unknown precious metal.

This information was last updated on .


Technical Characteristics

UNABLE TO DECODE
(CBME) UNABLE TO DECODE
BODY HEIGHT
(ADAU) 4.870 INCHES MINIMUM AND 4.870 INCHES MINIMUM AND 4.880 INCHES MAXIMUM4.880 INCHES MAXIMUM
BODY LENGTH
(ADAQ) 3.526 INCHES MINIMUM AND 3.526 INCHES MINIMUM AND 3.536 INCHES MAXIMUM3.536 INCHES MAXIMUM
BODY WIDTH
(ADAT) 2.995 INCHES MINIMUM AND 2.995 INCHES MINIMUM AND 3.005 INCHES MAXIMUM3.005 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH
(ABKQ) 2.937 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.937 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH
(ABKR) 2.437 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.437 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING
(ACZB) 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPE
(AKNA) HERMETICALLY SEALEDHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIP
(ACZC) SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
NOMINAL THREAD SIZE
(CQJX) 0.164 INCHES SINGLE GROUP
MOUNTING FACILITY QUANTITY
(AKPV) 4 SINGLE GROUP4 SINGLE GROUP
MOUNTING METHOD
(AXGY) THREADED HOLE SINGLE GROUPTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATOR
(AARG) NOT ESTABLISHEDNOT ESTABLISHED
THREAD SERIES DESIGNATOR
(THSD) UNC SINGLE GROUP
WINDING FUNCTION AND QUANTITY
(BPLC) 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT
(CRBZ) 960.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 114.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY86.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 86.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE
(CWJS) 86.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY628.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY114.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING
(CRMJ) 22.0 WATTS SINGLE COMPONENT SINGLE PRIMARY
TERMINAL TYPE AND QUANTITY
(TTQY) 8 STANDOFF, SOLDER LUG
UNABLE TO DECODE
(AAJF) UNABLE TO DECODE
UNABLE TO DECODE
(CQLC) UNABLE TO DECODE

Manufacturer Part Numbers


Related Inventory

140-007-33-32C4
5310007749427
Condition NE
WASHER
Readily Available
7671C140-007-33-32C4
5310-00-774-9427
Condition NE
WASHER, RECESSE
Readily Available
140-007-41-39D5
5310007749428
Condition NS
WASHER
Readily Available


 
Top