NSN 5990-01-105-4954, 5990011054954
RESOLVER,ELECTRICAL,LINEAR

Federal Supply Classification
FSC 5990 - Synchros and Resolvers
National Item Identification Number
NIIN 011054954
Codification Country
United States
Item Name Code
INC 31780
Criticality
(Y) This item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Hazardous Material Indicator Code
(N) There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials.
Availability: Readily Available Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 5990-01-105-4954
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 5990-01-105-4954


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 5990-01-105-4954

National Stock Number (NSN) 5990-01-105-4954, or NIIN 011054954, (resolver,electrical,linear) was assigned December 23, 1980 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 4 manufacturer part numbers associated with this NSN. 2 of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 4 suppliers. Today, 4 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, 3 suppliers are deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years, with the most recent procurement date of Nov 20, 2017. There have been 3 contracts issued for this part number, with 4 awards given. There is minimal competition for this NSN. The US Government has awarded contracts to 3 different suppliers. The last contract numbers awarded were: SPE7M518P2511, SPM4A111G0001, SPM4A111G0001, SPM7MC11M2229. The total value of the awarded contracts has been US$ 30,433.72.

This NSN is somewhat common among different platforms, belonging to 2 different weapons systems.

There has been very little demand for this national stock number. The demand for this NSN originated from less than 5 countries. Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on May 22, 2008, this NSN's acquisition method was noted as: Suitable for Competitive Acquisition. (Potential sources shall include dealers/distributors.) The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 31780. [AN ITEM CONSISTING OF A STATOR AND ROTOR INDUCTIVELY COUPLED WHICH PROVIDES ACCURATE LINEAR INDICATION OF SHAFT ROTATION ABOUT A REFERENCE POSITION IN THE FORM OF A POLARIZED VOLTAGE WHOSE MAGNITUDE IS PROPORTIONAL TO ANGULAR DISPLACEMENT AND PHASE RELATIONSHIP INDICATES DIRECTION OF SHAFT ROTATION. ITS WINDINGS AND SLOTS ARE NOT UNIFORMLY DISTRIBUTED, BUT INSTEAD ARE DELIBERATELY MODIFIED TO PRODUCE A LINEAR OUTPUT WHICH IS USUALLY LIMITED TO LESS THAN PLUS OR MINUS 90 DEGREES OF EFFECTIVE ELECTRICAL TRAVEL. NORMALLY IT HAS ONLY ONE ENERGIZATION WINDING AND ONE OUTPUT WINDING. SEE ALSO RESOLVER, ELECTRICAL.]. This item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application. There is no data in the HMIRS and the NSN is in an FSC not generally suspected of containing hazardous materials. NSN 5990011054954 does not contain precious metals.

This NSN is associated to Schedule B 9018903000: anesthetic instruments and appliances and parts and accessories. The Schedule B End Use is listed as medicinal equipment. NAICS classification category 339112: surgical and medical instrument manufacturing.

This information was last updated on .


Technical Characteristics

ALIGNMENT HOLE QUANTITY
(AJVW) 4
BODY STYLE
(AAQL) STANDARD ROUND C
CRITICALITY CODE JUSTIFICATION
(CRTL) FEAT
END ITEM IDENTIFICATION
(AGAV) OLIVER PERRY CLASS FFG; FIRE CONTROL SYSTEM
FLANGE DIAMETER
(ABKK) 1.0270 INCHES MINIMUM AND 1.0650 INCHES MAXIMUM
FLANGE THICKNESS
(ABKU) 0.0900 INCHES MINIMUM AND 0.0960 INCHES MAXIMUM
FREQUENCY IN HERTZ
(AJSS) 400.0 NOMINAL
ROTOR INPUT VOLTAGE RATING IN VOLTS
(AJSR) 26.0 NOMINAL
ROTOR INPUT CURRENT RATING
(AJST) 0.033 AMPERES NOMINAL
ROTOR INPUT ELECTRICAL POWER RATING
(AJSV) 0.2 WATTS NOMINAL
SHOULDER DIAMETER
(AAVH) 0.9995 INCHES MINIMUM AND 1.0000 INCHES MAXIMUM
PILOT DIAMETER
(AAVL) 0.6245 INCHES MINIMUM AND 0.6250 INCHES MAXIMUM
SPECIAL FEATURES
(FEAT) WEAPON SYSTEM ESSENTIAL
UNDERCUT WIDTH
(ABPC) 0.0500 INCHES NOMINAL
UNDERCUT DIAMETER
(ABPA) 0.9750 INCHES NOMINAL
TERMINAL LOCATION
(CQTM) REAR
TERMINAL TYPE AND QUANTITY
(TTQY) 11 SCREW
BODY MATERIAL
(AAFZ) ANY ACCEPTABLE

Manufacturer Part Numbers


Related Inventory

CR2563-6-02
Condition NE
CHERRYLOK RIVET
Readily Available
CR2563-6-02
CR2563-6-2 CR256
Condition NE
CR2563-6-02 (Pa
Readily Available
CR9563-6-02
Condition NE
CHERRY MS RIVET
Readily Available
199-210
5305-01-314-9046
Screw
Readily Available
20-01830
4710014563602
Condition NS
TUBE
Readily Available
2052-5636-02
Military
Readily Available
810656-3602
Condition FN
DRIVESHAFT
Readily Available
4286996
2540-01-556-3602
Request


 
Top