ISO Group Logo
Defense and Aerospace
Supply Chain Partner
A Dynatech International Company


NSN 6625-01-029-4625, 6625010294625
OSCILLOSCOPE

Federal Supply Classification
FSC 6625 - Electrical and Electronic Properties Measuring and Testing Instruments
National Item Identification Number
NIIN 010294625
Codification Country
United States
Item Name Code
INC 00357
Criticality
(N) This item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Hazardous Material Indicator Code
(P) There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Availability: Request Qualified Suppliers: Currently qualifying suppliers

Manufacture or supply this part?
Join our growing community of certified suppliers.

Let Us Know
  CALL ABOUT NSN 6625-01-029-4625
Our client representatives are standing by to help fulfill your request.

+1-321-773-5710

  REQUEST QUOTE for 6625-01-029-4625


Have a list that needs to be quoted? Upload it here.

DLMS® Summary

National Stock Number 6625-01-029-4625

National Stock Number (NSN) 6625-01-029-4625, or NIIN 010294625, (oscilloscope) was assigned October 17, 1976 in the Federal Logistics Information System (FLIS). This NIIN is Available for Manual Assignment. This NSN does not replace any other NSNs.

There are 2 manufacturer part numbers associated with this NSN. One of those part number(s) are considered obsolete. The manufacturer part numbers were originally supplied by 3 suppliers. Today, 3 suppliers are listed as Active suppliers for this NSN. Of the active suppliers, only one supplier is deemed design controlled or valid supply parts.

This part number has not been procured by the US Government in over 5 years.

Based on a planned procurement review by the Primary Inventory Control Activity (PICA) on Apr 02, 1991, this NSN's acquisition method was noted as: Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer. The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

This NSN is assigned to Item Name Code (INC) 00357. [A TEST INSTRUMENT WHICH IS DESIGNED TO GIVE VISUAL INDICATIONS ON AN LCD DISPLAY OR A CATHODE RAY TUBE OF INSTANTANEOUS VALUES AND VARIATIONS IN ELECTRICAL VOLTAGE. IT CAN ALSO BE USED TO INDICATE ANY QUANTITY WHICH CAN BE CONVERTED INTO TERMS OF ELECTRICAL POTENTIAL. IT MAY INCLUDE AN INTEGRAL PULSE GENERATOR, THE OUTPUT OF WHICH CAN BE USED TO TRIGGER AN EXTERNAL COMPONENT; BE TRIGGERED BY PULSES FROM AN EXTERNAL SOURCE, OR IT MAY UTILIZE AN LCD DISPLAY OR A SPECIAL TYPE OF MULTIGUN CATHODE RAY TUBE AND CIRCUITRY WHICH PERMITS A TRACE(S) TO BE SUSTAINED AND DISPLAYED INDEFINITELY, AND THE TRACE(S) MAY BE ERASED WHEN DESIRED. FOR ITEMS WHICH ARE NOT SEPARABLE AND OPERABLE WHEN DETACHED FROM EQUIPMENT OF WHICH THEY ARE A PART (BUILT INTO OPERATIONAL EQUIPMENT), SEE INDICATOR (2) (AS MODIFIED); MONITOR (AS MODIFIED); AND RECORDER (AS MODIFIED). SEE ALSO OSCILLOGRAPH.]. This item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input). There is no information in the HMIRS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product. NSN 6625010294625 does not contain precious metals.

This NSN is associated to Schedule B 9030908030: parts and accessories of articles of schedule b subheading 9030.39. The Schedule B End Use is listed as measuring, testing, control instruments. NAICS classification category 334515: instrument manufacturing for measuring and testing electricity and electrical signals.

This information was last updated on .


Technical Characteristics

AMPLIFIER INPUT IMPEDANCE RATING PROVISION
(BHDT) NOT PROVIDED
ACCURACY RANGE IN PERCENT
(BDJD) -3.0/+3.0
FREQUENCY RESPONSE RATING
(BHDP) PROVIDED
MEASUREMENT RANGE STEPS
(BHFD) 0.2 TO 50 MV PER IN.; 0.1 TO 100 V PER IN.
TRACE STORAGE TUBE
(BHFH) NOT INCLUDED
PLUG IN UNIT FUNCTION AND QUANTITY
(BHFS) VERTICAL AMPLIFIER 1,HORIZONTAL AMPLIFIER 1
AMPLIFIER DEFLECTION SENSITIVITY PROVISION
(BHDD) NOT PROVIDED
ACCURACY RANGE IN PERCENT
(BDJD) -3.0 TO 3.0
AMPLITUDE CALIBRATING VOLTAGE WAVEFORM
(BHDZ) SQUARE WAVE
BEAM QUANTITY
(ATES) 2
CALIBRATING PEAK TO PEAK AMPLITUDE
(BHFB) 0.2 MILLIVOLTS MINIMUM AND 100.0 VOLTS MAXIMUM
CURRENT TYPE
(ACDC) AC
FREQUENCY RATING
(ACZB) 45.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM
OVERALL HEIGHT
(ABKW) 6.984 INCHES NOMINAL
OVERALL LENGTH
(ABHP) 20.703 INCHES NOMINAL
OVERALL WIDTH
(ABMK) 19.016 INCHES NOMINAL
MEASUREMENT RANGE QUANTITY
(BHFC) 2
MOUNTING METHOD
(AXGY) RACK
SCREEN SIZE
(BGQK) 5 INCH
PHASE
(FAAZ) SINGLE
VOLTAGE RATING
(AMSE) 90.0 VOLTS MINIMUM AND 272.0 VOLTS MAXIMUM
Y-AXIS FREQUENCY RESPONSE RATING
(BHDR) 100.0 MEGAHERTZ NOMINAL
SWEEP CIRCUITS
(BGQL) NOT INCLUDED
INPUT INTENSITY MODULATION FEATURE
(BHDH) NOT PROVIDED
PLATE DIRECT CONNECTION DEFLECTION SENSITIVITY PROVISION
(BHDL) NOT PROVIDED
CAMERA RECORDING DEVICE ACCOMMODATION
(BHFT) PROVIDED
CALIBRATED SCREEN SCALE
(BHFF) NOT INCLUDED

Manufacturer Part Numbers


Related Inventory



 